10%, 12 to 15 VDC Voltage Power supply Current consumption Power supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less Voltage type 0 to 5 VDC, 0 to 10 VDC Input signal Current type 4 to 20 mADC, 0 to 20 mADC Approximately 10 k Voltage type Input impedance Approximately 250 Current type 1 to 5 VDC (Load impedance: 1 k or more) Output accuracy:

How to Order Manifold Assembly Example (VV5F3-40) Closed center (24 VDC) VF3340-5GZ1 (1 set) Double solenoid (24 VDC) VF3240-5GZ1 (1 set) Single solenoid (24 VDC) VF3140-5GZ1 (3 sets) Manifold base (5 stations) VV5F3-40-052-02 U side 1 3 2 Stations D side VV5F3-40-052-02 1 set (Type 40, 5-station manifold base part no.) VF3140-5GZ1 3 sets (Single solenoid part no.)

Flat terminal 2A 2B 2C 2D 2E 2F 2G 2H 2V 2J 2K 2L 2M 2N 2P 2Q 2R 2S 2W 2T 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC Enter symbols in the order below when ordering a combination of electrical option, other option, etc.

Load voltage 24 VDC, 100 VAC 24 VDC, 100 VAC, 200 VAC 24 VDC (10 to 28 VDC) 24 VDC (10 to 28 VDC) 28 VDC or less 28 VDC or less Load current range Indicator light Type Auto switch model D-C73 D-B54 D-H7B D-K59 D-H7A1 D-G59 Application Relay, PLC Relay, PLC 24 VDC relay, PLC 5 to 40 mA, 5 to 20 mA Reed switch 5 to 50 mA, 5 to 25 mA, 5 to 12.5 mA 5 to 40 mA 5 to 40 mA 40 mA or less 40 mA or

40 Me LEY 0 0.1 0.2 0.3 0.4 0.5 0 0.0 0.3 0.6 0.9 1.2 1.5 0 m Vertical Work load [kg] Work load [kg] LES 200 200 LEPY LEPS LEPY LEPS 160 160 L8 [mm] L8 [mm] 120 120 LER Z 80 80 L8 LEH 40 40 0 0.1 0.2 0.3 0.4 0.5 0 0.0 0.3 0.6 0.9 1.2 1.5 0 Me LEY -X5 m Work load [kg] Work load [kg] 11LEFS 11LEJS 25ALEC LEC S LEC SS-T LEC Y Motorless LAT LZ LC3F2 387 LEPS Series Step Motor (Servo/24 VDC)

240 VAC Conduit Example) VXN Z Z 1A 1 2 A (With surge voltage suppressor) 24 VAC 12 VDC 12 VDC 24 VDC Electrical option Other option Faston terminal 100 VAC 110 VAC 200 VAC 230 VAC DIN terminal (With surge voltage suppressor) 48 VAC 2G 2H 2V 2J 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 2K 2L 100 VAC 110 VAC 200 VAC 230 VAC 2M 2N 2P 2Q 2R 2S Conduit terminal (With surge voltage suppressor) 48

110VAC 5 ~ 20 mA NCD-J016 16 D-C76 Grommet PLC 4 ~ 8 VDC 20 mA Double Rod Clevis NY-J010B 10 24V AC/DC or less 50mA NY-J016B 16 D-C80 Grommet PLC 48V AC/DC 40mA Rod Jam Nut JM-005 8 100V AC/DC 20mA JM-006 10 D-C73C Connector PLC 24 VDC 5 ~ 40 mA JM-02 16 D-C80C Connector PLC 24V AC/DC 50 mA Mounting Nut JM-025 8 or less JM-03 10 D-H7A1 Grommet PLC 40 mA 28 VDC JM-04 16 D-H7A2 Grommet PLC

(Example 1) Users system side To the thermo-chiller 24 VDC +24 VDC (Output) 1 2 +24 VDC (Input) EXT 24 VDC EXT 24 COM Power supply 14 24 COM (Output) 24 COM Run/Stop When using a users power supply, connect the 24 VDC + side to pin 2 and the COM side of each contact input signal to the users power COM.

NPN open collector Max 30 VDC, 50 mA NPN open collector Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less

Refer to the construction drawing of the actuator motor. 40 40 40 40 40 40 40 40 Air cylinder installation with an auto switch is forbidden in the shaded area. (2) When installing electric actuator LEY(G) or LEF series with an auto switch by side, leave a gap of 40 mm or more with respect to the position where the magnet passes.

28 VDC or less 40 mA or less 2.5 to 40 mA Load current 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating position .

28 VDC) 28 VDC or less Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Leakage current 100 A or less at 24 VDC 0.8 mA or less Indicator light Red LED lights up when turned ON.

40.3 Load OUT2 40 4.3 8 4 Sensor input Load Black OUT1 Main circuit Main circuit 7 3 Sensor Sensor Brown DC(+) DC(+) 2 6 + SMC FLOW SWITCH Blue DC() DC() 1 5 12 to 24 VDC 35.8 A 40 UNIT RESET -1 PNP (2 outputs) SET Load OUT2 8 4 3 x 7.2 (= 21.6) 8 x M3 Sensor input Load Black OUT1 7 3 6.4 Brown DC(+) DC(+) 2 6 + Blue DC() DC() 1 5 1 2 3 4 12 to 24 VDC 19.4 Terminal block numbers 5 6 7

10% PF3A7 H 12 to 24 VDC 10% 12 to 24 VDC PF2M7 PFMC 10% 18 to 30 VDC 10% PF3A7 H-L 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 21.6 to 30 VDC PF3A701H/ 702H-L 18 to 30 VDC 10% 18 to 30 VDC PF2M7-L PFMC-L 10% 21.6 to 30 VDC PF3A8 H-L Temperature characteristics (25C standard) 3% F.S. 1 digit (15 to 35C) 5% F.S. 1 digit (0 to 50C) 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) Monitor

Voltage C Specifications 24 VDC 12 VDC Symbol 5 6 Note) For symbol, refer to page 7.

V) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) 28 VDC or less Load voltage 5 to 40 mA 40 mA or less 80 mA or less Load current 1.5 V or less (0.8 V or less at 10 mA load current) 4 V or less 0.8 V or less Internal voltage drop Leakage current 100 A or less at 24 VDC 0.8 mA or less Operating position Red LED lights up Optimum operating position Green LED

OUT2 NC Sensor 8 Load 41.8 4 40.3 OUT1 40 4.3 Black Main circuit 7 3 Load Brown 6 2 + SMC FLOW SWITCH Blue 5 1 35.8 36 12 to 24 VDC Series PF2W5 A 40 UNIT RESET PF2W30-A SET Panel fitting dimension 3 x 7.2 (= 21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black 1 2 3 4 Main circuit 7 3 Load +0.5 0 Brown 19.4 6 2 + Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2W5 PF2W31-A View A The applicable

In-line Electrical entry direction 2-wire 3-wire Wiring type NPN PNP Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage 28 VDC or less 40 mA or less 2.5 to 40 mA Load current 0.8 V or less 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8

(Red Green Red) PLC: Programmable Logic Controller D-P4DWL/Z (With indicator light) D-P4DWL D-P4DWZ Auto switch model 24 VDC relay, PLC Applicable load 24 VDC (20 to 28 VDC) Load voltage 6 to 40 mA or less Load current 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current 40 ms or less Operating time Operating position . Red LED illuminates.