50/60 Hz 3 110 VAC 50/60 Hz 115 VAC 50/60 Hz 2 200 VAC 50/60 Hz 4 220 VAC 50/60 Hz 230 VAC 50/60 Hz E L E C T R I C A L E N T R Y M A N U A L O V E R R I D E G Grommett (Lead Wire Length: 300mm) H Grommett (Lead Wire Length: 600mm) L L Type Plug with Lead Wire LN L Type Plug without Lead Wire LO L Type Plug without Connector M M Type Plug with Lead Wire MN M Type Plug without Lead Wire MO

If the VAC side pressure to this product is interrupted while the power is still on, the internal solenoid valve will continue to operate and may cause a humming noise. Since this may shorten the life of the product, be sure to shut off the power when the VAC side pressure is shut off. 10.

200 VAC 55 1 2 110 VAC (115 V) 3 220 VAC (230 V) 4 U Vacuum switch Wiring specifications (Vacuum switch) Note) U, R are available only for 24 VDC.

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

Vertical Vertical Lateral Lateral ZPT VAC p. 33 p. 34 p. 51 p. 52 p. 69 p. 70 p. 87 p. 96 p. 105 p. 106 With adapter ZPR p. 35 p. 37 p. 53 p. 54 p. 71 p. 73 p. 88 p. 89 p. 97 p. 98 p. 107 p. 108 VAC VAC With adapter ZPY p. 39 p. 41 p. 55 p. 56 p. 75 p. 77 p. 90 p. 91 p. 99 p. 100 p. 109 p. 110 With adapter VAC VAC VAC VAC VAC ZPT p. 43 p. 57 p. 79 p. 92 p. 101 p. 111 With buffer ZPR p. 46

Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease.

(50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other VY1 G Option D: Type D DIN terminal Nil G None PPA With pressure gauge AL How to Order Pilot Valve Assembly SF4 1 G 80 Y: Type Y DIN terminal Rated coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Soft start-up valve

50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other

: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.

, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 2 3 Rc 1 8 01 C6 C8 One-touch fitting for 6 One-touch fitting for 8 3 position pressure center 4 Note) P , R1, R2 port: Rc 1/8 5 24 VDC 12 VDC 5 6 9 Manual override Other Option Electrical entry Nil: Non-locking push type B: Locking type B (Slotted) C: Locking type C (Manual) Grommet L plug connector M plug connector DIN

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC6V, Specification: Standard, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: -, Port Size: -, Connecting Tube Diameter: -, Pressure Rating(MPa): 1,

Body Style: B (Base Mounted w/Screws), Coil Voltage: V (6 VDC), Flow Rate: A (Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor)

Diode Surge voltage suppressor LED Indicator light It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC. [Low wattage [0.45 W] is available, too. For details, refer to catalog on page 4-18-4.]

Indicator light LED Can be used for 110 V and 115 VAC, 220 V and 230 VAC in common.

Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.

100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil A B Non-locking push type Non-locking extended type Locking slotted type 1 2 3 4 5 6 7 9 1 2 3 4 5 6 7 9 Electrical entry Grommet Conduit Conduit terminal DIN terminal DIN terminal with indicator light Option G C T Note) D DL Option Option Option Note) When the electrical entry

VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other 1 2 3 4 5 6 7 9 Coil rated voltage 1 2 3 4 5 6 7 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Electrical entry G C TNote) D DL Option Electrical entry/With indicator light/ surge voltage suppressor Grommet Conduit Conduit terminal DIN terminal DIN terminal with

Diode Surge voltage suppressor LED Indicator light It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC. [Low wattage [0.45 W] is available, too. For details, refer to catalog on page 4-18-4.]

Electrical entry of 2 port solenoid valve D : DIN connector DL: DIN connector (With indicator light) T : Conduit terminal TL: Conduit terminal (With indicator light) D0: DIN connector (Without connector) Voltage of 2 port solenoid valve 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC 794 Air Catch Sensor Series ISA2 How to Order For single and double notation type and

T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) 50 Main