1 y, z + A = 200 y, z + A = 300 1 y, z + A = 200 0.1 y, z + A = 300 0.01 0.1 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the
30 8 6 8 10 5 5 20 4 5 12 10 16 10 12 16 10 2 0 0 0 0 100 200 300 400 500 600 V (mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) -9- (1)(DC24V) LEFS40 (mm) 1) 200, 300, (400), 500, (600) (700), 800, (900), (1000) 50 60 (kg) ) 23 (mm/s) 2) 20500 10250 (mm/s 2) 3,000 (mm) 0.02 (mm) 20 10 (m/s 2) 3) 50/20 () 540 (%) 90 RH ) 56.4 (DC24V) A/B 800 / (V) DC2410%
Station 2 58 40 Station 20 346 328 3 74 56 4 90 72 5 106 88 6 122 104 7 138 120 8 154 136 9 170 152 10 186 168 11 202 184 12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 Station L1 L2 331 5 Port Solenoid Valve 10-SYJ5000 [ ]: AC Type 40: Bottom Ported/10-SS5YJ5-40Stations -M5 Grommet (G) Directional Control Valves Air Grippers Modular F. R.
MRQ Auto Switch Internal Circuit DD-90 20OUT () Weight OUT () Brown Contact protection box CD-P11 CD-P12 Reed switch (g) OUT ( ) D-90 D-97 Auto switch model OUT ( ) Blue Black line 5 5 0.5 Lead wire length (m) 23 23 3 D-97 37 37 5 Contact protection box CD-P12 Choke coil OUT (+) Brown Dimensions OUT (+) Reed switch Zener diode Zener diode D-90 OUT () OUT () Blue Black line Resistor LED
BS4-200 7-9-46
47 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Tie-rod Mounting Style
CN Connector GFCI Ground fault circuit interrupter EDV Electronic drain valve PE Protective earth SYMBOL WIRE COLOR (BK) Black (WH) White (GR) Gray (SY) Sky blue (BU) Blue IDF80/90 (BR) Brown 200/200,220VAC 1PH 50/60Hz (G/Y) Green/Yellow 7.4 Electric circuit IDF60/70/80/90 Series 7-4 IDX-OM-V022 Chapter 7 Documents IDF60/70-30 IDF80/90-30 SYMBOL DESCRIPTION CM Refrigerating compressor OLR
C37 20A 3/4 20 D 200 VAC N.O. Stainless steel E 230 VAC 6 D K L N.C. N.O.
900 800 700 600 G 500 400 300 200 100 0 1000 900 800 700 600 H 500 400 300 200 100 0 1000 900 800 700 600 I 500 400 300 200 100 0 1000 900 800 700 600 J 500 400 300 200 100 0 1000 900 800 700 600 K 500 400 300 200 100 0 When the cylinder is extended, the speed controller is metered-out, is connected with the cylinder directly, and its needle is fully open.
27 16 45 49.5 64 M14 x 1.5 14 4.5 14 50, 75, 100, 125, 150, 175, 200, 250, 300 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 x 1.5 21 7 18 T P L M N O Q X Z Bore size (mm) 32 40 50 63 1 8 Rc 41 34 5.5 M6 x 1 56 30 14 57.5 1 8 Rc 41 40 5.5 M6 x 1
VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and
Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension
This parameter is fixed when shipped, and cannot be modified. (200) Operation direction Direct3 (dir) or Reverse4 (rvS) can be selected. The default when shipped is direct (dir). setting 100% 200=dir 200=rvS Stroke 0% 0% 100% 0% 100% Input current Fig. 24 When the operation direction is modified, it is reflected on each item in accordance with Table 9.
-100 0.04 Table deflection (mm) 0.030 Table deflection (mm) Table deflection (mm) 0.05 MXS2575 MXS2575 MGQ MXS2540 MXS2550 0.025 0.04 0.03 MXS2550 MXS2540 0.020 0.03 MXS2530 MGG 0.02 0.015 MXS2530 MXS2520 MXS2510 MXS2520 MXS2510 0.02 0.010 MGC 0.01 0.01 0.005 MGF 0 100 200 300 400 0 100 200 300 400 0 50 100 150 200 250 300 Load (N) Load (N) Load (N) CY1 MY1 3.11-9 Series MXS How to Select
0.03 0.06 MXS2075 0.020 MXS2030 0.02 0.04 MXS2020 0.015 MXS2050 MXS2040 MXS2010 0.010 MXS2030 MXS2020 MXS2010 0.01 0.02 0.005 100 200 300 0 0 0 100 200 300 160 120 80 40 240 200 Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf Load N 1N = 0.2248 lbf 25 25 25 Lr=154mm 0.040 0.07 0.05 MXS25-125 MXS25-150 MXS25-100 0.035 MXS25-150 MXS25-75 MXS25-50 MXS25-40 MXS25-30 MXS25-20 MXS25-10 0.06 MXS25
st 300 st or less Over 100 st 200 st or less Over 25 st 100 st or less WA Bore size (mm) X YY YL Z PA PB PW R S T U VA VB Q 25 st or less Over 300 st Over 200 st 300 st or less Over 100 st 200 st or less Over 25 st 100 st or less 28 11 14.5 25.5 74 89 52 64 174 210 75 90 198 236 156 188 180 210 140 166 28 48 52 72 128 148 200 220 300 320 42 35 54 47 92 85 128 121 178 171 M12 x 1.75 100 124
200 Lower limit 100 100 Lower limit 0 0 10 20 30 40 0 10 20 30 40 0 Transfer speed [m/min] Transfer speed [m/min] RS2H63-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.2 = 0.1 1,000 900 800 700 600 500 400 300 200 100 0 1,000 900 800 700 600 500 400 300 200 100 0 Mass of transferred object m [kg] Mass of transferred object m [kg] 63 Operating range Upper limit
HRSH150/200-A: 2 pcs. are used per unit HRS-S0214 Dust-proof filter (Upper) 1 pc. HRSH100/150/200-A: 2 pcs. are used per unit HRS-S0185 Dust-proof filter 1 pc.
Dimensions ZP2-Z002 ZP2-Z003 40 20 0.1 0.2 A A 20 0.1 0.2 40 A A 20 40 A-A A-A w q q w 11 20 9 18 90 4 x 4 90 4 x 4 4 e e 5 5 () 12 () 4 x 2.4 1.8 1.5 4 x 2.4 1.5 0.9 20 9.4 Component Parts Component Parts Part no. Description No. ZP2-Z2A ZP2-Z2B ZP2-Z2C Material PTFE FKM Aluminum alloy Note Clear anodized Part no. Description No.
AXT661-34A-, for 200/220 VAC.
Potential malfunction may occur if a rectified AC with voltage rise (dv/dt) at zero crossing exceeds 40V /200 sec. Always establish a connection to a ground for safety.