Driver: C (CC-Link Direct Input Type, Absolute Encoder), Power Supply Voltage: 2 (200 to 230 VAC, 50/60 Hz; for LECSC2-T), Motor: T8 [AC Servo Motor (T8), 400W, Absolute Encoder]
Driver: C (CC-Link Direct Input Type, Absolute Encoder), Power Supply Voltage: 2 (200 to 230 VAC, 50/60 Hz; for LECSC2-T), Motor: T9 [AC Servo Motor (T9), 750W, Absolute Encoder]
Body Type: T (Body Ported), Valve Option: V (for Vacuum), Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: None, Port Size: 02 (1/4, 8A)
Solenoid: 1 (Single Solenoid), Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Manual Override/Classification: Non-locking Push Style (Flush), Thread: N (NPT)
Solenoid: 1 (Single Solenoid), Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light/Surge Voltage Suppressor: None, Manual Override/Classification: Non-locking Push Style (Flush), Thread: N (NPT)
Body Type: O (For Manifold), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 2 (200 Vac, 50/60 Hz), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: None
Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0242100/2400 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 200 to 230 VAC (50/60 Hz)CE/UL?
Cooling Capacity: 9.5 kW Air/ 11.0kW Water, Cooling Method: Air-cooled Refrigeration, Power Supply: 20 [3-phase 200VAC (50 Hz); 3-phase 200 to 230VAC (60 Hz)], Option: Applicable to DI Water Piping
Body Type: Body Ported, Valve Option: Continuous Duty, Voltage: 200 VAC, 50/60 Hz, Electrical Entry: DIN Terminal, Light & Surge Suppressor: Surge Voltage Suppressor, Port Size: 1/4, 8A, Thread: -, CE/UKCA Compliant: -
Body Type: Body Ported, Valve Option: for Vacuum, Voltage: 200 VAC, 50/60 Hz, Electrical Entry: Conduit Terminal, Light & Surge Suppressor: Surge Voltage Suppressor, Port Size: 1/4, 8A, Thread: -, CE/UKCA Compliant: -
Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0242100/2400 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 200 to 230 VAC (50/60 Hz)CE/UL?
Cooling Capacity: 090 (9.5 kW Air/ 11.0kW Water), Cooling Method: A (Air-cooled Refrigeration), Power Supply: 20 [3-phase 200VAC (50 Hz); 3-phase 200 to 230VAC (60 Hz)], Option: P (with Pump Inverter)
Body Type: T (Body Ported), Valve Option: Standard, Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: G (Grommet, 300mm Lead), Light & Surge Suppressor: S (Surge Voltage Suppressor), Port Size: 02 (1/4, 8A)
Solenoid: 1 (Single Solenoid), Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override/Classification: Non-locking Push Style (Flush)
Body Type: Body Ported, Valve Option: Standard, Voltage: 200 VAC, 50/60 Hz, Electrical Entry: Grommet, 300mm Lead, Light & Surge Suppressor: Surge Voltage Suppressor, Port Size: 1/4, 8A, Thread: NPT, CE/UKCA Compliant: -
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Body Type: T (Body Ported), Valve Option: E (Continuous Duty), Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: S (Surge Voltage Suppressor), Port Size: 02 (1/4, 8A)
Body Type: T (Body Ported), Valve Option: V (for Vacuum), Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: S (Surge Voltage Suppressor), Port Size: 02 (1/4, 8A)
Body Type: T (Body Ported), Valve Option: Standard, Voltage: 2 (200 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light w/Surge Voltage Suppressor), Port Size: 02 (1/4, 8A)
Body Type: For Manifold, Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 200 Vac, 50/60 Hz, Electrical Entry: with Connector, Light_Surge Voltage Suppressor: None, Port Size: -, Thread Type: -, Bracket: -, CE Compliant: -