M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

, OUT 6) ARM5AA1-310-1 (One-touch fittings: IN 8, OUT 6) 0.35 0.7 Outlet pressure (MPa) Outlet pressure (MPa) 0.30 0.6 0.25 0.5 0.20 0.4 0.15 0.3 0.10 0.2 0.05 0.1 0 0 50 100 150 250 200 0 0 50 100 150 200 250 Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics (Representative Value) Outlet pressure 0.2 MPa Flow rate 20 l/min (ANR) Condition: Inlet pressure 0.7 MPa Outlet

Note 2) For manifold dimensions including elbow fitting, refer to page 23. 2 n L L: Dimensions n: Stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 L1 L2 L3 L4 185.5 198 210.5 210.5 223 223 235.5 248 248 260.5 260.5 273 285.5 285.5 123 135.5 135.5 148 148 160.5 173 173 185.5 112.5 125 125 137.5 137.5 150 162.5 162.5 175 175 187.5 200 200 212.5 212.5 225 237.5 237.5 250 250

Mass (g) D-B30 D-B30J D-B31 D-B31J D-B35 D-B35J Auto switch model 190 250 190 250 190 250 0.5 Lead wire length (m) Auto Switch Internal Circuit 3 368 368 368 D-B30 5 462 462 462 Contacts protection resistance Brown (Terminal 1) Blue (Terminal 2) Contacts (Magnetism detection) Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m.

OPTIONS AND AUXILIARY EQUIPMENT (3) Outline drawing (a) EMC filter HF3010A-UN [Unit: mm] 3-M4 4-5.5 7 3-M4 M4 32 2 110 4 85 2 IN Approx.41 258 4 65 4 273 2 288 4 300 5 13 29 13.

LB LC LD LE LF LH LT Model LA F H MM U FD FT FX FY ZX ZY Model M 6 x 1.0 depth 12 200 (233) 224 (257) CRA1L50 CRA1F50 41 62 9 4 39 44 108 4.5 114 9 13 90 50 110 81 M 6 x 1.0 depth 12 235 (273.5) 263 (301.5) CRA1L63 CRA1F63 48 76 11 5 45 55 127 5 136 11.5 15 105 59 130 101 M8 x 1.25 depth 16 274 (318) 316 (360) CRA1L80 CRA1F80 58 92 13 5 55 67 154 6 165 13.5 18 130 76 160 119 M10 x 1.5 depth

LB LC LD LE LF LH LT Model LA MM U FD FT FX FY ZX ZY F H Model M 6 x 1.0 depth 12 200 (233) 224 (257) CRA1L50 CRA1F50 41 62 9 44 4 39 108 4.5 114 9 13 90 50 110 81 M 6 x 1.0 depth 12 235 (273.5) 263 (301.5) CRA1L63 CRA1F63 48 76 11 55 5 45 127 5 136 11.5 15 105 59 130 101 M8 x 1.25 depth 16 274 (318) 316 (360) CRA1L80 CRA1F80 58 92 13 67 5 55 154 6 165 13.5 18 130 76 160 119 M10 x 1.5 depth

VO307 00 Q CE compliant VO301 00 X302 Coil rated voltage 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Component Parts No.

115 120 125 150 175 200 225 250 85 90 95 100 105 110 115 120 125 130 155 180 205 230 255 100 105 110 115 120 125 130 135 140 145 170 195 220 245 270 120 125 130 135 140 145 150 155 160 165 190 215 240 265 290 55 60 65 70 75 80 85 90 95 100 125 150 55 60 65 70 75 80 85 90 95 100 125 150 65 70 75 80 85 90 95 100 105 110 135 160 185 210 75 80 85 90 95 100 105 110 115 120 145 170 195 220 245

Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.

R 63 80 100 63 80 100 63 80 100 350 to 1100 308 107 54 86 108 192 30 72 14 29 119 16 300mm or more 350 to 1200 355 131 66 104 128 224 35 89 19 40 145 23 400mm or more 350 to 1300 410 131 66 128 143 262 40 110 19 40 145 23 500mm or more 20

M2 Find the value M2max when Va = 250 mm/s from Graph (13) c. m x g Calculate for the impact load. Since the impact is absorbed by shock absorber, the bumper coefficient = 1/100 FE = 1.4 x Va x m x g x = 1.4 x 250 x 5.5 x 9.8 x 1/100 = 188.7 [N] Dynamic moment M1 Examine M1E. Calculate the collision speed V.

In the case of 110/220 VAC, the VDW10 is 3 W and the VDW20/30 is 3.5 W. Note 4) Vibration resistance No malfunction when tested with one sweep of 5 to 200 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states.

External Grip Internal Grip MHS2-32D MHS2-32D 150 150 Pressure 0.6 MPa Pressure 0.6 MPa 120 120 0.5 MPa 0.5 MPa Gripping force (N) Gripping force (N) 0.4 MPa 0.4 MPa 90 90 0.3 MPa 0.3 MPa 60 60 0.2 MPa 0.2 MPa F 30 30 0.1 MPa 0.1 MPa 0 0 10 10 20 20 30 30 40 40 50 50 F Gripping point L (mm) Gripping point L (mm) MHS2-40D MHS2-40D 250 250 Pressure 0.6 MPa Pressure 0.6 MPa 200 200 Gripping

Dimensions (mm) Equation L1=10.5n+14.5, L2=10.5n+25 n: Station (Max.16) n L 1 2 46 56.5 225 235.5 6 88 98.5 262.5 273 3 56.5 67 237.5 248 7 98.5 109 275 285.5 4 67 77.5 250 260.5 8 109 119.5 287.5 298 5 77.5 88 250 260.5 9 119.5 130 300 310.5 10 130 140.5 312.5 323 14 172 182.5 350 360.5 11 140.5 151 312.5 323 15 182.5 193 362.5 373 12 151 161.5 325 335.5 16 13 161.5 172 337.5 348 L1 L2 L3

Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.

250 262.5 (L4) 135.5 135.5 148 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273 Stations are counted from the D side Courtesy of Steven Engineering, Inc. !

Panel adapter B ZS-22-02 Specifications PF2W300/301 PF2W330/331 Model Flow rate measurement range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Set flow rate range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Minimum set unit Note 1) 0.05 l/min 0.1 l/min 0.5 l/min 1 l/min Accumulated pulse flow rate exchange 0.05 l/pulse 0.1 l/pulse

220 77.5 80 50 40 18 9 88 35 9 4.6 74 3 226 187 38 110 235 93 96 70 50 20 11 115 44.5 11 6.4 84 3.3 303 264 43 110 282 98 96 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 279 45 110 292 98 101 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 280 46 110 297 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.