Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/230, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 130mm
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 50mm
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 180mm
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 150mm
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 100mm
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/70, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/230, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 130mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 50mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 180mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Model Air flow [m3/min] Heat generation [W] HECR002-A 2 600 HECR004-A 5 1300 HECR006-A 5 1400 HECR008-A 7 1700 HECR010-A 7 2500 HECR008-W 0.2 200 HECR012-W 0.4 250 Operating Environment/Storage Environment Warning Facility Water Caution 1. Keep within the specified ambient temperature and humidity range.
, 300, 350, 400 MGCM Slide bearing 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000 *Short stroke or intermediate stroke(except above stroke): Manufactured upon receipt of order 3.20-2 Compact Guide Cylinder Series MGC Specifications MGCll20 MGCll25 MGCll32 MGCll40
Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 Electronic gear denominator *3 PA07 1 250 150 75 300 200 100 375 250 125 Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection *4 PA14 0 1(+Counter motors side) Adaptive tuning mode PB01 0 0 Load to motor inertia moment ratio PB06 7 7 Machine resonance suppression
For details on how the models are indicated, refer to How to Order. 315 or more 50 200 or more 63 CCT63 120 or more 80 75 or more 100 1164 Air-hydro Unit CC Series Data (A) Volume of Cylinder/Capacity of Converter 160 140 125 100 800 700 600 300 250 200 180 10,000 8,000 500 400 80 6,000 5,000 4,000 300 600 500 63 3,000 200 400 50 2,000 300 40 Effective oil level stroke (mm) 500 200 1,000
Data (A) Volume of Cylinder/Capacity of Converter 160 140 180 125 300 250 800 700 600 200 Selection Step 100 10,000 8,000 6,000 5,000 4,000 500 400 Step (1) Select the bore size of air-hydro cylinder 80 300 First of all, select a bore size from data (D)
When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.