SMC Corporation of America
Elite Part Number Search
Search Results "PFM510S-F01-2-S"

Nozzle Diameter: ø1.0mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in G1/8, VAC: Screw-in G1/8, EXH: Screw-in G1/8, Accessories: -

Nozzle Diameter: ø1.0mm, Vacuum Pressure: -90 kPa, SUP: Screw-in G1/8, VAC: Screw-in G1/8, EXH: Screw-in G1/8, Accessories: -

Nozzle Diameter: ø0.7mm, Vacuum Pressure: -90 kPa, SUP: Screw-in G1/8, VAC: Screw-in G1/8, EXH: Screw-in G1/8, Accessories: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Body Size: 20, Pipe Thread: F (G), Port Size: 01 (1/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: S (Water Drop Removal Type), Semi-standard: None

Body Size: 20 (Applicable AC Size: AC20), Handle Operation: W (Double Action), Thread Type: F (G), Port Size: 01 (1/8), Mounting: without Mounting Option, Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: Resin, Flow Direction: R (Flow Direction: Right to Left), Unit: Unit of Product Label: MPa

Body Size: 20 (Applicable AC Size: AC20), Handle Operation: Single Action, Thread Type: F (G), Port Size: 01 (1/8), Mounting: without Mounting Option, Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

[Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, 95 lb

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION

also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, F29, 135 lb