10 mA (2 V or less at 40 mA) 4 V or less 100 A or less at 24 VDC Current leakage 0.8 mA or less Operating position .

, 2 SU0 No option 04 1/2 Size 1, 2 SUQW DeviceNet serial interface (Note) 06 3/4 Size 2, 3 10 1 Size 3 TU1 Terminal Box Note: Please ask available protocol to SMC Conduit Port Thread (for terminal box only) Symbol Port Thread NIL Rc (PT) F G (PF) N NPT T NPTF Locations and sizes of port 4(A), 2(B) Symbol Port location Applicable ISO size 02 Side 1/4 Size 1 03 Side 3/8 Size 1, 2 04 Side

Note) Use Series AS-F with -X214 for the throttle valve. 2. Cracking pressure is a pressure at which the valve starts opening and not a pressure at which the valve is fully open. 15-8-7 Flow Control Equipment Precautions Series ASP Series ASS Caution on Design Selection Warning Warning 1. This product cannot be used for accurate and precise intermediate stops of the actuator.

solenoid valves can be used at all of the manifold stations.

Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

A 0x00,0xFA Checksum ASCII:LRC RTU:CRC F,F 0x39,0x73 Trailer CR/LF None Total quantity of byte 15 7 Response message at an ambient temperature of 25.0 3.13 Register Map HRL Series 3-26 HRX-OM-Y120 Chapter 4 Communication alarm function Chapter 4 Communication alarm function Monitors whether the serial communication is sent/received properly between the product and the customers device.

(Full span) 6 l/min (ANR) (at supply pressure 0.9 MPa) Free Within 1% F.S.

Field name Example RTU mode ASCII mode (HEX) character data binary data Header : None Device address 0x01 0,1 0x01 Function 0x04 0,4 0x04 Quantity of bytes to read 0x02 0,2 0x02 Information of 0009h(Data display 1) 0x00FA 0,0,F,A 0x00,0xFA Checksum ASCII:LRC RTU:CRC F,F 0x39,0x73 Trailer CR/LF None Total quantity of byte 15 7 * Response message at an ambient temperature of 25.0C 3.13 Register

the body side, while in case of A2 and B2, at the manifold side.

M H L M E W Y 1/8 LQ1H11-F LQ1H12-F LQ1H21-F LQ1H22-F LQ1H23-F LQ1H24-F LQ1H31-F LQ1H32-F LQ1H33-F LQ1H34-F LQ1H35-F LQ1H36-F LQ1H41-F LQ1H42-F LQ1H43-F LQ1H44-F LQ1H51-F LQ1H52-F LQ1H53-F LQ1H54-F LQ1H61-F LQ1H62-F LQ1H63-F LQ1H64-F 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 11.5 18.5 10 10 26.5 1/8" Class 1 Rc (NPT) Port size VC 18.5 35 1/8" 16.5 14 15 14 L VDW 21.5

AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 Material Part no.

With pressure at rod cover port Low friction side B (Example of application q) With pressure at head cover port Low friction side F (Example of application w) In both cases, as long as the outside pressure moves the piston rod, low friction can result in the direction of extension and retraction.

Return voltage is 20% or more of the rated value at AC power and 5% or more at the DC power. The allowable voltage fluctuation rate is 10% of the rated voltage value for both AC and DC.

SUP/EXH block assembly mounting position They will be assembled in the order listed starting at the first station at the D side even if the connector box is located at either end. When ordering with the double wiring specification, specify it in order, beginning with the 1 station on the D side. When special wiring is required, use the manifold specification sheet.

Bore size (mm) Auto switch model 40 50 63 80 100 D-A5/A6/A59W/F5/J5 D-F5W/J59W/F5NTL/F59F D-A3/A44/G39/K39 D-B5/B64/B59W/G5/K59 D-G5W/K59W/G59F/G5NTL BT-04 BT-04 BT-06 BT-08 BT-08 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-06 BA-08 BA-10 D-A3C/A44C/G39C/K39C BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 D-Z7/Z80/Y59/Y69/Y7P D-Y7PV/Y7W/Y7WV BA4-040 BA4-040 BA4-063 BA4-080 BA4-080 Mounting

To rotate the servo motor at 3000r/min in the open collector system (200kpulse/s), set the electronic gear as follows. f CMX CDV = N0 60 10 f : Input pulse frequency [pulse/s] N0 : Servo motor speed [r/min] 200 103 CMX CDV = 3000 60 10 CMX CDV = 3000 60 10 200 103 = 3000 10 60 20 = 15 6 4 11 4.

AS420-03 AN30-03 12 x 1 m D AS420-04 AN40-04 SGP15A x 1 m 1723 3 Port 3 Position Valve Body Ported VEX3 Series How to Order Air operated Pilot solenoid VEX3 B 12 0 01 1 Air operated VEX3 D B 5 1 12 2 01 Pilot solenoid Operation type Option 1 External pilot solenoid 2 Internal pilot solenoid Nil None Thread type Nil Rc F G N NPT T NPTF Body size Port size B Bracket (VEX312 only) Body size

MG Bore size (mm) 40 Bore size (mm) 40 Model Model 50 63 80 100 50 63 80 100 MGP D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B6 D-B59W D-G5/K59 D-G5W/J59W D-G5BAL D-G59F/G5NTL D-A3C/A44C D-G39C/K39C MGQ BT-04 BT-04 BT-06 BT-08 BT-08 BA-04 BA-05 BA-06 BA-08 BA-10 MGG MGC BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 To order

If the controller is ordered separately, the mounting parts for the assembly must be ordered at the same time. Ex d WARNING (ND9200, ND7200, ND9300): Use a cable gland and blind plug with suitable Ex d certification. For ambient temperature over 70 C / 158 F use a heat resistant cable and cable gland suitable for at least 90 C / 194 F.