Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
DIGITAL FLOW SWITCH, MODULAR. DIGITAL FLOW SWITCH. 490.00000 lb. P65.
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
M = W x 9.8 (Ln + An)/1000 Correction value of moment center position distance An: Table (3) Ma = K Mmax Workpiece mounting coefficient K: Fig. (3) Allowable moment coefficient : Graph (2) Maximum allowable moment Mmax: Table (4) 2 = M/Ma Find the allowable static moment Ma (Nm). Find the load factor 2 of the static moment.
Examine for Mep (20+6.8) Mep=1/333.6 =0.3 1000 We=42420/100=33.6 A2=6.8 Meap=0.71.7=1.19 =0.7 Mp max.=1.7 3=0.3/1.19=0.252 (Ln+An) Me=1/3We 1000 Load equivalent to collision We=4WV/100 Corrected value for center position distance of moment An : Table 3 Calculate allowable kinetic moment Mea(Nm). Mea=M max.
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: N (w/o Lead Wire and M8 Connector), Unit Specification: Unit Selection Function, Option 2: R (w/Bracket)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
Rated Flow Range: 10 to 1000 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: w/o Lead Wire and M8 Connector, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 400 lb
DIGITAL FLOW SWITCH, DIGITAL FLOW SWITCH, MODULAR, P65, 400 lb
Coil rated voltage 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 1 2 3 Electrical entry 110 to 120 VAC, 50/60 Hz T E H G Grommet (Lead wire: 300 mm) Grommet (Lead wire: 600 mm) 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC Grommet terminal Conduit terminal D With connector DO Without connector L With lead wire LN Without lead wire LO Without connector M With lead wire MN Without lead wire 7 240 VAC, 50/60
", Knob-operated type 3/8", Air-operated type 1/2", Air-operated type 1/2", Max. operating pressure 1.6 MPa Pressure increase ratio: Twice Z Note) Note) Thread type: NPT, NPTF Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. 11A Note) Pressure increase ratio: 2 to 4 times 1/4", Knob-operated type Option Option Symbol Nil G N S GN GS LN
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)