SMC Corporation of America
Elite Part Number Search
Search Results "NCJ2B16-100SR"

Magnet: Built-in, Mounting: Basic, Bore: Ø10 (3/8 inch), Stroke: 1 Inch, Action: Spring Return, Port Location: In-line, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 5m, Number: 1 pc.

Magnet: Built-in, Mounting: Flange, Bore: Ø10 (3/8 inch), Stroke: 1 Inch, Action: Spring Return, Port Location: In-line, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 1 pc.

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Return, Head Cover Port: Axial, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Return, Head Cover Port: Axial, Auto Switch: A--With Switch Rail, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Return, Head Cover Port: Axial, Auto Switch: A--With Switch Rail, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Return, Head Cover Port: Axial, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Return, Head Cover Port: Axial, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Return, Head Cover Port: Axial, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 1/4", Stroke(mm): 1", Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: H7A2, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of

Cylinder (Tube) Inner Diameter(φ): 1/4", Stroke(mm): 1", Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: H7A2, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of

Series NCJ2 miniature cylinders available in spring return, spring extend, or double acting all offer stainless steel tubing and stainless steel rods. Available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Basic, foot, front flange and double rear clevis mounting options. Auto-switch capable. Other features include non-rotating, double rod, rubber bumpers and a stainless

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches