Bore Size: 16mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 12mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 8mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: Magnet and Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Specification: Standard Type (Not Clean Room), Bore Size: 8 mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Metal Stopper Both Ends, Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 20mm, Action: Single Acting N.C., Finger Position: Standard, Body Option: Basic, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -
Note 2) Safety allowance x3 at 20C Note 3) To calculate flow factor for longer lengths of tube divide factor for 1 metre by actual length in meters.
MPa Proof pressure (20C) 20 to 80C Ambient and fluid temperature JIS B 0203 (Taper threads for piping) Thread Note 1) Refer to Particulate Generation Grade Classifications.
Features 1 New New 5 port solenoid valve series SY9000 Cv 2.8 (base mounted type with sub-plate) Interface regulator series ARBY3000/5000 (for series SY3000/5000) High speed response: 10ms (SY3000 single solenoid, 0.5MPa, 20C) (representative value) The innovative design of the pilot valve makes it possible to achieve a short response time of 10ms while consuming only a half watt of power
Standard Specifications/Single Unit (Standard Dew Point 20C) Membrane Air Dryer Series IDG Model Standard dew point: 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters. -20C low dew point just by installing in air pressure line.
The value of the minimum bending radius is measured at the temperature of 20C as shown below. KP LQ MQR Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. T T Fixed end IDK 3.
Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter change rate of 10% or less.
(mm) 7.3 5.8 4.4 2.8 8.8 Black (B) White (W) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Blue (BU) Fixed end Translucent (N) Fluid Air 20C 0.8 Max.
Characteristics 65 or less Cable length (L) 9 stations{ Conductor resistance /km, 20C 10 stations{ 11 stations{ 1.5 m AXT100-DS25-015 Cable 25 core x 24AWG 3 m AXT100-DS25-030 Voltage limit V, 1 min, AC SOL.A SOL.B 1000 5 m AXT100-DS25-050 12 stations{ SOL.B COM. Connector terminal no.
MPa) Outlet air set temperature Outlet air set temperature 68F (20C) 77F (25C) Air flow Air flow 10.6 scfm (300 L/min [ANR]) 17.7 scfm (500 L/min [ANR]) E E IDH4 or IDH6 are selected from Data .
Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less.
12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C
Characteristics 65 or less Cable length (L) Conductor resistance /km, 20C Voltage limit V, 1 min, AC 1.5 m 3 m 5 m AXT100-DS25-015 ~ = 10 Cable 25 core x 24AWG AXT100-DS25-030 1000 AXT100-DS25-050 L Insulation resistance Mkm, 20C For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. 5 or more 16 44 Note) The min. bending radius of D-sub cable
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.