AFF Port size 3/4B 1/8B 01 02 03 06 10 14 AMl 1B 1/4B Note) Please refer to p.4.7-7 about "How to Order" case assembly. 3/8B 11/2B Related products 2B 20 04 1/2B Option combinations Available Not available D J R AMG150 AMG250 AMG350 AMG450 Applicable model Accessories Options C C D J R Accessories/Optional specification AMG550 AMG650 AMG850 Symbol N.C. auto drain N.O. auto drain Drain guide
Symbol Order Made P.4.6-21 4.6-15 Micro Mist Separator with Prefilter Series AMH AMH150 to AMH850 How to Order AMH 250 03 J B Body size Options J Drain guide 1/4B female thread R IN/OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Description None Bracket Symbol T Element service indicator B N.C.auto drain C N.O.auto drain D Note) Refer to p.4.7-7
Symbol: A3 Symbol: A2 Symbol: A1 Symbol: A0 C DA C0.5 30 30 A H H H W1 T H Symbol: A7 Symbol: A6 Symbol: A5 Symbol: A4 30 RD RD B AL MM AL MM H L L W H 30 30 H 30 H Symbol: A11 Symbol: A10 Symbol: A9 Symbol: A8 WA C C0.5 file chamfer AL B MM R sphere TP R sphere DC 30 H W1 T H H H 117 Simple Specials C85/C75 Series Single Acting, Spring Return/Extend Single Acting, Spring Return/Extend
Accessory (Option) Applicable model Bracket assembly With cap bolt and spring washer AME150 AME250 AME350 AME450 AME550 AME650 AME850 BM51 BM52 BM53 BM54 BM55 BM56 BM57 AME 250 03 R B HA Option specifications AT R IN-OUT reversal direction Body size Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 ID Nil Bracket B Nil AMG Port
8 @1 r @4 w MX MTS MY 12 to 40 CY @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Rod cross section for 12, 16, 20, and 25 D-X 20Rod cross section for 32 and 40 Data With end lock 12 to 40 y !7 !6 q !
Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 50 20 40 Pressure loss (kPa) Pressure loss (kPa) 15 30 10 20 5 10 Flow rate (l/min) 0 200 0 50 100 150200250 300 400 350 450 500 20 50 100 150 Flow rate (l/min) Sensor Unit Construction PF2A710/750 PF2A510/550 Component Parts No. q w e r t Description
Air operated style fluid control valve Vacuum valve Vacuum pad 2(A) 1(P) 2(A) 1(P) 2(A) 1(P) 2(A) 3(P) 3(R) 3(R) 3(R) 1(R) Atmospheric air or micro pressure for vacuum release 22 Multi-purpose Valve Series VCA Direct Operated 2 Port Solenoid Valve for Air Improved durability (Nearly twice the life of the previous series) Operating resistance of moving parts reduced for improved longevity
Refer to gauge guide (P.94). r w q w q Sample Order Number Port 2P 4PL 01 S BP10 e r t 0 4 4 4 4 1 MPA e 2P 4PL qIN wOUT erGauge port (Inlet) Specifications BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1006 2 to 60 psig (0.014 to 0.4 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) BP1020 15 to 200 psig (0.1 to 1.4
2 r t i !4 y q e !3 o w u !0 !1 M: Rod end male thread Component Parts Replacement Parts: Seal Kit No. Description Material Note Bore size (mm) Kit no. Contents Cylinder tube Aluminum alloy Hard anodized 1 20 25 32 40 50 63 Piston Aluminum alloy Chromated CQ2B20-PS 2 Stainless steel CQ2B25-PS 20, 25 Piston rod 3 Set of nos. above !2, !3, !
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No. Description Rod cover Head cover Cylinder tube Piston Spacer for switch type Description Qty. Note Material Qty.
Initial value Recommended value No Servomotor Rotation Direction can Pn000 0 0001 (+Counter motors side ) Tuning-less Function Related Switch Pn170 1401 1401 Electronic Gear Ratio (Numerator) *3 Pn20E 4 65536 Electronic Gear Ratio (Denominator) *3 Pn210 1 1250 750 375 1500 1000 500 1875 1250 625 LEFS25(L,R) LEFS32(L,R) LEFS40(L,R) Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8
No Servomotor Rotation Direction can Pn000 0 0001 (+Counter motors side ) Tuning-less Function Related Switch Pn170 1401 1401 Electronic Gear Ratio (Numerator) *1 Pn20E 4 65536 Electronic Gear Ratio (Denominator) *3 Pn210 1 1250 750 375 1500 1000 500 1875 1250 625 LEFS25(L,R) LEFS32(L,R) LEFS40(L,R) Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para.
y OUT side IN side OUT side IN side Communication cable (With connector on both sides) t u t r EX260 Series EX600 Series Specifications Description Communication cable (With connector on one side) Field-wireable connector Part no.
Flow direction (Right Left) Nil Rc1/4 F G1/4 *1 Nil Flow direction (Left Right ) R Flow direction (Right Left) *1: Conforming to ISO16030 *1: Conforming to ISO16030 Square embedded type pressure gauge Round type pressure gauge Refer to the WEB catalog for details.
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Model Port size Note 2) INLET OUTLET Rated flow rate (L/min) FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 1B 1/2B 20 1B 3/4B 50 1 1/2B 1B 100 1 1/2B 1 1/4B 150 2B 1 1/2B 200 2B 2B 300 2 1/2B 2 1/2B 450 3B 3B 600 3 1/2B 3 1/2B 750 4B 4B 900 Note 2) Both flange
Move the piston to the stroke end of the side that will be filled with oil, and perform steps q through r in the same sequence as described above. MK/MK2 Environment UAvoid use near fire. UDon't use in the clean room. RSQ/RSG Mounting RSH UInstall the converter vertically. UInstall the converter at a position that is higher than the cylinder.