Size: 16, Motor Mounting Position: In-line; Motor Cover Direction: Bottom, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 250mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable
Size: 32, Motor Mounting Position: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 250mm, Motor Option: w/Motor Cover, Rod End Thread: Male Rod End, Mounting: -, Actuator Cable Type: -, Cable Length: -, Controller/Driver Type: -, I/O Cable Length: -, Protocol: -, Suffix: -, Controller/Driver Mounting: -, Communication Plug: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: Double foot, Auto Switches: Without auto
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Rubber Bumper
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Rubber Bumper
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options:
Magnet: Built-in, Mounting: Through Hole, Overall Length: Standard, Bore Size: 2 1/2", Stroke: 2 1/2", Body Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 4", Stroke: 2 1/2", Body Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: None, Speed Control Type: Right Angle, Applicable Tubing: 3/8", Suffix: Required Selection w/Speed Control
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 9/16", Stroke: 2 1/2", Body Option: Rubber Bumper & Male Rod End, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -, X Option: -
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Rubber Bumper
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Rubber Bumper
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options:
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: Double foot, Auto Switches: Without auto
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 32, Motor Mounting Position: D (In-line), Motor Type: Step Motor (Servo/24 VDC), Lead Screw: C (LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male Rod End), Mounting: Ends Tapped (Standard), Actuator Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: D (In-line), Motor Type: Step Motor (Servo/24 VDC), Lead Screw: C (LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male Rod End), Mounting: Ends Tapped (Standard), Actuator Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 3 (3m), Controller/Driver Type: 6P (LECA6, PNP, Step Data Input