Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: DIN
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: DIN
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: DIN Rail
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: DIN Rail
Table Accuracy: High Precision, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option
Oscillation Angle A: 320°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.8, Size: 30, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator cable
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 1.34481 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 2.09439 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 1.98416 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY32PPPPPPPPPPP20 to 500
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 115/60/1 Flow Rate: 12.5 LPM , 12.5 LPM, Max Pressure: 12.5 PSIG / 121 in H20 / 300 mbar , 12.5 PSIG / 121 in H20 / 300 mbar, Max Vacuum: 10.3 in HgV / -350 mbar , 10.3 in HgV / -350 mbar, Voltage (60 Hz): 115, Frequency (Hz): 60, Phase: 1-phase, Item Dimensions: Length: 4.21 in / 107 mm Width
Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 115/60/1 Flow Rate: 12.5 LPM , 12.5 LPM, Max Pressure: 12.5 PSIG / 121 in H20 / 300 mbar , 12.5 PSIG / 121 in H20 / 300 mbar, Max Vacuum: 10.3 in HgV / -350 mbar , 10.3 in HgV / -350 mbar, Voltage (60 Hz): 115, Frequency (Hz): 60, Phase: 1-phase, Item Dimensions: Length: 4.21 in / 107 mm Width
Series: 350 [3 Port COM (Single Unit)], Voltage: 5 (24VDC), Electrical Entry: W (Grommet / Molded), Orifice: 3 [350 (3 Port) ø3], Port Size: 01 [1/8 (6A)], Thread: N (NPT), Material: L (Stainless Steel Body, FKM Seal, Class B Coil)
flange: G Lateral load applied to the rod end fR [N] 0.3 26 38 18 36 24 48 M 1.0 G G N U U M 0.5 19 29 14 27 18 36 W W W C8516 Rod (side) 0.7 16 23 11 22 14 30 C8512 0.3 10 15 6 15 9 20 C8510 Head ( side ) C858 0.5 6 10 4 10 6 14 0.1 0.7 4 8 3 8 4 11 Clevis: N Rod trunnion: U 0.3 24 36 17 35 22 46 0.5 18 27 12 26 16 W W 34 0.7 14 22 10 21 13 28 0.01 (40)1 (40)1 (40)1 (40)1 (100)1 0.3 80 400 350
Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500