Fig. 9-4 Cooling capacity(HRS030--20-(BJMT)) 9.5 Heating capacity 9.5.1 HRS030-A-20-(BJMT) 1000 1000 Ambient Ambient temperatur temperatur 800 e e Heating capacityW 800 Heating capacityW 40 32 25 20 5 40 32 25 20 5 600 600 400 400 200 200 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz Fig. 9-5 Heating capacity(HRS030

Status (6): Alarm will be generated after 600 seconds that is set for "AS.23: Range over detection timer" after the circulating fluid temperature exceeds the threshold of "AS.04".

Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Start time of circulating fluid temperature monitor 600 0 to 9 TEMPOUTSTART SEC No.24 circulating fluid temperature monitor is outside of the time range 5 0 to 600 TEMPOUTOVER SEC screen No.25 screen Dust filter replacement time*2 5000 1 to 9 FLTRTIME H No.26 screen DI filter replacement time*1 5000 1 to 9 DITIME H No.27 screen Temperature control speed 0 -10 to 10 CTRLSPEED piping). 2 Can

Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Slider type LEKFS series 2.1 Specification AC servo motorMotor typeS*/T*) Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000

Fig. 8.4-2 Cooling capacity(HRSE018-A-10) 8.4.3 HRSE012-A-20/23-(T) 1600 1600 Ambient Ambient Temperature Temperature 1400 1400 25 35 40 25 35 40 1200 1200 Cooling capacity[W] Cooling capacity[W] 1000 1000 800 800 600 600 400 400 200 200 0 0 0 10 20 30 40 0 10 20 30 40 Circurating fluid temperature[] Circurating fluid temperature[] 60Hz 50Hz The cooling capacity will be reduced by 100W when

600 600 15 30 76 38 103 9.0 144 3.2 27 13 31 188 9.0 35 19 183 195 127 154 45 50 70 30 12 22 74 12 80 76 18 95 160 1000 (1001 to 1200) 101 (105) 15 (23) 105 (140) 59 (64) 130 (170) 43 (48) 170 (179) 0.032 0.059 63 1200 600 600 600 18 11.5 11.5 110 40 92 49 107 166 3.2 34 16 24 206 40 23 196 212 148 162 50 59 86 40 16 28 90 16 93 92 25 171 1000 (1001 to 1400) 119 (124) 18 (28) 130 (164) 76

Single solenoid Lead wire length AXT661-12AL 300 mm 600 mm 1000 mm 2000 mm 3000 mm AXT661-12AL 300 mm 600 mm 1000 mm 2000 mm 3000 mm Socket only (3 pcs.)

Inch size ARJ310F-N01 5/32" 1/4" 03 07 14-4-11 9 Series ARJ310 Flow Characteristics Inlet pressure: 0.7 MPa ARJ310-01 ARJ310F-01-04 ARJ310F-01-06 0.7 0.7 0.7 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow

Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.

600 600 15 30 76 38 103 9.0 144 3.2 27 13 31 188 9.0 35 19 183 195 127 154 45 50 70 30 12 22 74 12 80 76 18 95 160 1000 (1001 to 1200) 170 (179) 101 (105) 15 (23) 105 (140) 59 (64) 130 (170) 43 (48) 0.032 0.059 63 1200 600 600 600 18 11.5 11.5 110 40 92 49 107 166 3.2 34 16 24 206 40 23 196 212 148 162 50 59 86 40 16 28 90 16 93 92 25 171 MGZ 1000 (1001 to 1400) 204 (215) 119 (124) 18 (28

[Space required for maintenance] Front: 600 mm Back: 600 mm Top: 600 mm Right side: 600 mm Left side: 600 mm Caution 1. Provide ventilation space. Unless a necessary ventilation space for each piece of equipment is provided, this product could cool poorly or stall.

Standard Stroke (mm) Model Standard stroke CXS20 20, 25, 30, 35, 40, 45, 50, 60, 70, 75, 80, 90, 100 CXS25 CXS32 25, 30, 35, 40, 45, 50, 60, 70, 75, 80, 90, 100 Table (1) Allowable Kinetic Energy at Piston Impact 20 25 32 Bore size (mm) Theoretical Output Piston speed (mm/s) 50 to 700 50 to 600 50 to 600 (N) Allowable kinetic energy (J) 0.17 0.27 0.32 Model Operating direction Operating pressure

magnet With rod boot Spring lock Grommet Grommet Mounting 3 wire 3 wire 2 wire D-F59 D-F59W D-J59W D-F5P D-F5PW D-F5BAL (2 color indicator) (2 color indicator) 2 wire 4 wire 3 wire D-J59 D-F59F D-F5NTL D-F5LF (2 color indicator) D-A53 D-A54 D-A56 D-A64 D-A67 D-A59W (2 color indicator) Single rod Series MNB 40 50 63 80 100 25 to 500 Cylinder with Lock Series MNB Tie-rod mounting type 25 to 600

600 600 L2 M2 400 400 400 L2 mm L2 mm L2 mm Rolling Yawing W 200 200 200 L2 M2 0 10 20 30 0 20 40 60 0 2 4 6 8 10 Work load (W) kg Work load (W) kg Work load (W) kg W 3000 2000 2000 a=1000 a=1000 a=1000 2000 L3 mm L3 mm L3 mm L3 1000 1000 1000 a=2000 a=2000 W a=2000 a=3000 a=3000 a=3000 M3 a 0 20 40 60 0 2 4 6 8 10 0 10 20 30 Work load (W) kg Work load (W) kg Work load (W) kg 600 600 600

, 1000 200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

18.5 13.5 13.5 9 9 50.4 40.7 [42] 111.6 92.4 [95] [ ] for AC Other dimensions are the same as the grommet type. [ ] for AC Other dimensions are the same as the grommet type. 25 Series SYJ3000 Valve Drawings 2 Position Single (mm) 10 10 G H Grommet (G), (H) : SYJ3140-M5 5 10 33.5 Manual override 22 4 23.2 (Mounting holes) B A 11 2.5 17.5 A B 53.6(GZ:54.6) [54.6] G : About 300 H : About 600

nominal size (mm) Limited flow (dm3/min) Standard effective oil level stroke (mm) 100 300 750 200 600 1510 3660 300 890 2260 5490 400 1190 3010 7320 500 1480 3770 9150 600 4520 10980 700 12810 800 14640 50 150 63 100 160 36 88 217 Limited flow shows the limit of converter oil level speed (200 mm/s) which can maintain stability of converter oil level.

1 y, z + A = 200 y, z + A = 300 1 y, z + A = 200 0.1 y, z + A = 300 0.01 0.1 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the