Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
The length of the cable between stations (L1, L2 ... Ln) must be 0.5 m or more. 2. The total cable length must be L1 + L2 ... + Ln 50. 3.
Number No. r t y u i SS070A 01 1A O-ring FKM SS070A-80A-1 10 VFN Port size Clip Stainless steel SS070A-80A-2 10 With 3.18/2 barb fitting With 4/2.5 barb fitting 01 02 Metal joint Stainless steel SS070A-80A-3 10 Leaf spring Stainless steel SS070A-80A-4 10 Mounting bracket Stainless steel SS070A-80A-5 10 < U Side End Plate Assembly > w U side end plate assembly no.
C37 Series 200 Symbol Port size PB 300 SUS M5 01 02 M5 1/8 (6A) 1/4 (8A) Thread type Nil F N Rc G NPT Piping to 3 Port Valve N.O. Port Caution Socket Electricity 1. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. Cover Others 1. Material NBR: Nitrile rubber FKM: Fluoro rubber = FPM Trade names: Viton, Dai-El, etc.
Material Manifold material Seal material NBR FKM EPDM NBR FKM EPDM Symbol Nil A B G H J Thread type Rc G NPT Nil F N Brass (C37) 1 D side 2 3 4 5 U side Stainless steel OUT port size Stations 02 Series 20 p p 2 stations Symbol Port size 10 p 30 p p M5 01 02 10 M5 1/8 (6A) 1/4 (8A) 10 stations Note) IN port sizes are as follows. 10: 1/8 (6A) 20: 1/4 (8A) 30: 3/8 (10A) How to Order Valves
Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21