Note 1) 1 station 01 16 stations Note) Number of terminals 16 Note 2) Refer to page 2-4216 for details.
*The bracket cannot be retrofitted later. *2 position single only SYJA7 20 1 01 Body ported SYJA7 40 2 Base mounted Symbol Body ported Port size Thread type Type of actuation Nil Rc G NPT NPTF Without sub-plate Nil 2 position single 2 position double 4 3 2 position double 2 position single 2 1 1/8 With sub-plate 01 F N T 2(B) (A)4 2(B) (A)4 3 position closed center 1/4 With sub-plate 02 3
KQ2 KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 3/8
Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMZ0024 Data
Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).
[F90] Setting of all functions is completed : Setting of each function Every time the SET button is pressed, the display moves to the next function in order of "Setting of each function" on page 55. Set by using the UP and DOWN buttons.
Alarm Code.01 to 21,24,25,28,29,32: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. *Alarm code 02 and 16 are alarms only for HRZ008-L/L1-F. *Alarm code 28 is an alarm only for HRZ010-W*S-F.
Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 VN Symbol 01 02 01 02 02 03 03 04 04 06 10 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Body class Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Symbol 01 02 01 02 02 03 03 04 04 06 10 Body class LQ3 Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
17.9 21.4 20.8 21.1 23.1 23.9 25.3 23.3 24.9 25.2 27.2 35.3 27.8 29.5 31.8 27.8 29.5 31.8 33.6 35.2 27.9 28.2 30.2 31.0 32.4 32.5 34.2 34.5 36.4 44.5 39.3 41.0 43.3 39.3 41.0 43.3 47.9 49.5 17 17 18 19 19 32 33 33 34 36 54 55 57 54 55 57 94 96 14.5 5 32" 1 8 14.2 36.1 31.1 30.5 25.5 14.3 3 16" 16.5 17 18.5 14.5 16.5 17 18.5 21 17 18.5 21 17 18.5 21 21 22 12 1 4" 5 16" 5 32" 3 16" 17.2 17
1 Valve 2, 3 diagnostics 01 2 Valve 4, 5 diagnostics 01 3 Valve 6, 7 diagnostics 01 4 Valve 8, 9 diagnostics 01 5 Valve 10, 11 diagnostics 01 6 Valve 12, 13 diagnostics 01 7 Valve 14, 15 diagnostics 01 Valve diagnostics 2 . 5-5 Valve diagnostics 2 Bit 0 Valve 16, 17 diagnostics 01 1 Valve 18, 19 diagnostics 01 2 Valve 20, 21 diagnostics 01 3 Valve 22, 23 diagnostics 01 4 Valve 24, 25
ATTACHMENTS / ACCESSORIES OPTIONS PART NUMBER Attachments / Accessories (Options) part number Section Model For AC10*-A For AC20*-B For AC25*-B For AC30*-B For AC40*-B For AC40*-06-B For AC50*-B For AC55*-B For AC60*-B Descriptio Round type Standard G27-10-R1 G36-10-01 G46-10-01 Note1) Pressure gauge G27-10-R1 G36-4-01 G46-4-01 0.2 MPa setting Round type Standard G36-10-01-L G46-10-01-L
PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes
Regulator Model Tool size Amount of retightening Reference torque AR20M-D 34/38 2.0+/-0.2 N m 2 to 5 notch AR30M-D 52/55 3.5+/-0.3 N m AR40M-D 52/55 4.0+/-0.4 N m 7-2. Pressure gauge (round type) 1) Pressure gauge mounting (round type) Before mounting the pressure gauge onto the pressure gauge port of the regulator, confirm that sealing material has been applied to the pressure gauge.
:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
01 90-VQ2000 Series compatible with secondary batteries For blanking manual specification 90 Material restriction OUT side port size Rc 1/8 01 IN side port size Rc 1/8 01 *Specifications and dimensions for the 90-series are the same as standard products. 7 3 Port Solenoid Valve Pilot Operated Poppet Type Rubber Seal 90-VP300/500 Series How to Order A 2 4 3 VP D Z 5 90 02 Series compatible
C10: 10 (SMC) N11: 3/8" (SMC) (C12: 12 (SMC) (In case of double sided type)) [Communication connector D-sub] (DIN rail clamping screw) R R R BUS OUT BUS 76.7 76.5 12 3 12 3 3 72 BUS IN X 49.5 B B B B B B B B P X P X P 12 PWR PWR 30 25 A 1 1 A 1 A A A A A A A 55 25 13 (7.5) 18 55 One-touch fitting [4(A), 2(B) port] Applicable tube O.D.
18 02 14 03 38 04 12 D I M E N S I O N S S E R I E S (N)ASN H Hexagonal Width Port Size Model D Min Max Across Flats 20.5 23.3 8 M5x0.8 (N)ASN2-M5 10 30 34 14 1/8 (N)ASN2-01 15 34.2 38.2 17 1/4 (N)ASN2-02 20 37 41 21 3/8 (N)ASN2-03 25 49 55 24 1/2 (N)ASN2-04 30 y, South San Francisco, CA 94080-6370 !
Model Option AR20(K)-B AR25(K)-B AR30(K)-B AR40(K)-B AR40(K)-06-B AR50(K)-B AR60(K)-B Bracket assembly *1 AR23P-270AS AR28P-270AS AR33P-270AS AR43P-270AS AR52P-270AS Set nut AR23P-260S AR28P-260S AR33P-260S AR43P-260S *2 Round type *3 Standard G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G36-4-01 G46-4-01 Round type *3 (with color zone) Standard G36-10-01-L G46-10-01-L Pressure gauge 0.02