SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-AN-46-M"

plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to page 4-4-61 for dimensions with connector cable.

Note 6) Product other than the option R is not equipped with an earth leakage breaker. Please purchase an appropriate earth leakage breaker separately.

Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are other applicable auto switches than listed, refer to page 8-29-10 for details.

The indicator is designed to turn red when an output value exceeds the limit.

0.5 m 0.5 m 0.5 m 3 m 3 m 3 m 3 m Option 500 Note) This product is for overseas use only according to the new Measurement Law.

3 m 5 m None Solid state switches marked with are produced upon receipt of order.

Bore size 20, 25/MLGPM20/25 (Slide bearing) Operating Range as Stopper for MLGPM20/25 100 25 l = 50 mm l = 50 mm Weight of transferred object: m (kg) m m 20 5 10 10 20 30 40 50 Transfer speed: (m/min) Bore size 32 to 100/MLGPM32 to 100 (Slide bearing) Operating Range as Stopper for MLGPM32 to 100 1000 Weight of transferred object: m (kg) l = 50 mm l = 50 mm 100 m m 80 63 50 40 32 100

Lead wire length symbols: 0.5 m Nil (Example) Y69A 3 m L (Example) Y69AL 5 m Z (Example) Y69AZ Since there are applicable auto switches other than the listed above, refer to page 9-11-29.

Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].

Model Model ZPR20B-0-A10 ZPR40B-0-A14 23.5 38.5 49.3 67.1 12.4 47.5 58.3 76.1 24.4 20 25 40 48 16 22 43 34 10.5 25 ZPR25B-0-A10 19 ZPR50B-0-A14 50 24 39 49.8 67.6 15.6 51.5 62.3 80.1 32.4 28 57 27 53 38 14 ZPR32B-0-A10 32 29 44 54.8 72.6 18.9 37 34 Dimensions by Stroke Dimensions by Stroke 40 50 J K: 6 K: 8 Model 20 25 32 J K: 4 K: 6 K: 8 G H G H L M L M Model G H G H G H L M L M L M ZPRB10

Do not use the product with flammable fluid Fire or an explosion may result. Only air is an applicable fluid. Do not use the product in a place where static electricity is a problem. Otherwise failure or malfunction of the system can result. If using the product in an interlocking circuit Provide a double interlocking system, for example a mechanical system.

switch (Lm) Operating angle m: The value of the individual switchs movement range Lm as represented by an angle.

plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to page 646 for dimensions with connector cable.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.

is an inductive load. w In a case where the wiring load is greater than 5 m.

The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount the switch in a location where there is no vibration (Display: greater than 98 m/s2, Sensor: 4.9 m/s2 or less), or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

JS20, 32, 40, 63 Center of sphere M M U U D J F B E G P A R H (mm) Max. thread depth P Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) Weight (kg) M A B C D E F G H J Model JS10-4-070 JS16-5-080 8.5 0.5 17 0.01 14.4 M4 x 0.7 9.5 12 4 7 4.7 80 4 1.5 26 12 0.5 23 19 0.02 M5 x 0.8 13.5 16 6 10 5.8 210 5 2 34.5 JS20-8-125 JS32-10-125 15.5 0.5 29.9

52 46 55 63 69 S 33 36 40 46 50 52 Z 46 52 56 65 73 79 6 10 16 20 25 32 7 9 12 16 20 24 6 depth 4.8 6 depth 5 7.6 depth 6.5 9.3 depth 8 9.3 depth 9 11 depth 11.5 5 7 Free Mount Cylinder Double Acting, Single Rod Series CU Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 D-F9W 22 (24.5) ( ): Denotes the values of D-A93.

(The switch will stay ON all the time.) 1) For an auto switch without a connect protection circuit, use a contact protection box when the wire length is 5 m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30 m long, it is not able to adequately absorb the rush current and its life may be reduced.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. However, please contact SMC for water-resistant products of 12 and 16. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.