TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.
4.5 5 5 5.5 6.5 D-P4DW 4 4 4 4.5 4 4.5 4.5 D-A9l/A9lV 7 7.5 8.5 9.5 9.5 10.5 12 D-Z7l/Z80 7.5 8.5 7.5 9.5 9.5 10.5 13 D-A5l/A6l 9 9 10 11 11 11 10 D-A59W 13 13 13 14 14 15 17 D-A3l/A44 9 9 10 11 11 11 10 * The switch mounting bolt is supplied with the switch.
(Equivalent tightening torque: T) Approx. G D Approx. C 6 13.5 4.5 0.5 Width across flats F 10 Tightening torque: Tighten within 10 1 Nm. G1/4 (mm) Part no.
t t t B1 H1 (mm) (mm) (mm) Dd9 Applicable bore size (mm) L L Dd9 d l l d m t Snap ring Snap ring t m Part No.
(t) is given for 10 l tank by the graph. Then, the charging time (T) for a 100 l tank, T = t x = 49 x = 49 (s). V 10 10 10 T = t x = 110 x = 110 (s). V 10 10 10 T = t x = 2.4 x = 24 (s).
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room specification 104 Dust seal specification 110 TSUBAKI CABLEVEYOR specification 122 Construction 134 Mounting 140 Non-standard
Dd9 L d l m t -0.030 -0.040 IY-J015 1.5 C type 5 for shaft 10 5 12.2 0.7 16.6 4.8 -0.040 -0.076 IY-G02 1.5 C type 8 for shaft 16 8 16.2 0.9 21 7.6 -0.040 -0.076 IY-G03 1.55 C type 10 for shaft 20 10 20.2 1.15 25.6 9.6 -0.040 -0.076 IY-G04 1.55 C type 10 for shaft 25, 28 10 36.2 1.15 41.6 9.6 9 10 Lateral Load Resisting Compact Low Friction Cylinder Series MQM 6, 10, 16, 20, 25 Metal Seal
With control unit Centralized wiring/Supply port left Individual wiring/Supply port right Centralized wiring air catch sensor ISA2-HE41P Terminal box Individual wiring air catch sensor 2 port solenoid valve 2 port solenoid valve ISA2-GE41 Regulator 3 0 3 0 3 0 3 0 3 0 3 0 Supply port Supply port P P P P P P T T T T T T U U U U U U E E E E E E L L L L L L S S S L L L S S S L L L 6 9 6 9 6
10 12 16 20 5 6.5 8 10 14 15 18 20 7 10 12 14 4 4 5 5 5 5 8 10 * Refer to P.2.3-18 for detail of the rod end nut and mounting brackets.
is D side mounting only. 10 Note) 10 stations Note) Base 01T/10/40: 2 to 10 stations Base 01C/01F: 2 to 8 stations Including stations of control unit.
Option R . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 EARTH LEAKAGE BREAKER SPECIFICATION . 10-1 10.3 CONNECTION OF POWER SUPPLY. 10-2 Chapter 11 Option T . 11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 OPERATION / ERROR SIGNAL OUTPUT . 11-1 11.3 REMOTE OPERATION . 11-2 11.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 11-3 11.5 ELECTRIC CIRCUIT . 11-4 Chapter 12 Option V . 12-1
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
2 t r @2 @1 #3 #4 @9 #1 #2 @5 @7 @4 @6 CY1H10 CY1H10-B CY1H10-BS CY1H10@3 @8 #0 t Material Note Component Parts No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 No.
Analog In An Analog input value from a System Input (A01, A02, A03, ... A08) FB Value An analog value contained in a Function Block (T, t, N, n, Direct set, etc.) Word Comparison a 16 bit output value from a Function Block 6.1 Boolean Function Block It is possible to express the Logic functions in the form of an equation.
0 n r Ro 18 tio ta or tio ta t f n r Ro fla an le ge ng of si +10 0 0 Ro 19 tat or io t f n r fla an gle ge sin of With external stopper For 90 For 180 Single flat Single flat 5 A A e ng ng ng le le ra ad ad t ju ju en st st m m m st en en ju t r t r ad an an gle ge ge An 5 5 B port A port B port A port 90 A 5 ng ge le an ad t r ju en st m 180 Note) The drawings show the rotation range
8 15 13 3.5 1.5 5.5 200 200 10 107.0 108.0 107.5 108.0 154 164 12.5 10.5 17.5 15.5 6 4 8
8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room specification 104 Dust seal specification 110 TSUBAKI CABLEVEYOR specification 122 Construction 134 Mounting 140 Non-standard Motor Mounting