Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 1 pc., Lock Unit Built-in Magnet: Built-in, Lock

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: M5 x 0.8, Auto Switches: A93, Lead Wire Length(m): 5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches:

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 1000mm, Option: Rear Cushion, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc., Lock

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: Rc, Stroke: 900mm, Option: Rear Cushion, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc., Lock Unit

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches:

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY1F MAGNETICALLY COUPLED CYL, IE, 25MM CY1F DBL-ACT AUTO-SW, 6.17294 lb

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,