, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.
Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Average speed Series (mm/s) VQC 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SQ VQ0149-C4 VQ0 VQ4 800 700 600 500 400 300 200
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VQC2000 800 700 600 500 400 300 200 100 0 VQC4000 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open.
, 800 125 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Up to 2000 Note 1) Manufacture of intermediate strokes is possible.
, 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Refer to Minimum Stroke for Auto Switch Mounting on page 54.
, 800 100 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 125 Intermediate strokes are available.
pressure P1 (MPa) IR IR2010-02 IR2010-02 IR2010-02 Supply pressure: 0.7 MPa Back pressure: 0.7 MPa 0.7 VEX 0.204 0.4 0.6 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) AMR 0.202 0.5 Set point 0.3 ITV 0.4 0.200 0.2 0.3 IC 0.198 0.2 0.1 VBA 0.1 0.196 VE 0 100 200 300 400 500 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 0 100 200 300 400 500 600 700 800 900 1.0 Flow rate ( /min (ANR))
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read
(Value in the initial stage) Series SYJA700 JIS symbol How to Order Manifold Base 2 4 SYJA52 SYJA72 2 4 SYJA51 SYJA71 2 4 2 4 Uses the same manifold valve as the SYJ500, 700 series. (A) 2 (A) 2 SS3YJA5 Specify the same manifold part number as SS3YJ5. (SYJA500) SS3YJA7 Specify the same manifold part number as SS3YJ7.
For further details on solenoid valves, refer to the SMC solenoid valve catalog "SYJ 300, 500, 700" (E143-B). Note 3) Solenoid valves are shipped facing downward (flange side), but can be rotated to face upward.
Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160
Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Average speed Series (mm/s) VQC 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SQ VQ0149-C4 VQ0 VQ4 800 700 600 500 400 300 200
AN10-C06 AN10-C07 AN15-C08 AN20-C10 AN20-C11 AN30-C12 A C (Resin sintered body) 36.5 11 14.5 1/4 45 13 20 8 Body (Resin) 10 57.5 16.5 30.5 3/8 71.5 20 43.5 12 d 3 Silencer Metal Body Type Series AN00 RoHS How to Order Noise reduction 30 dB(A) Low back pressure Easy mounting 500 AN 06 Port size Body size Thread type Symbol Port size Applicable model Type Symbol Symbol 06 10 12 14 20 500 600 700
Cylinder with Lock Series CNA Double acting 25 to 600 Double rod Series CNAW Lock unit is compact without any projections. 25 to 700 3.3-1 Series CNA/Precautions q Be sure to read before handling. Refer to p.0-39 to 0-46 for Safety Instructions and actuator cautions and auto switch precautions.
80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Symbol Specifications 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Heat resistant cylinder (150C) -XB6 Intermediate strokes are available.
-X1247 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500 600, 700, 800 20, 25 32, 40, 50 63, 80 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500, 600 700, 800, 900,1000 Intermediate strokes and strokes shorter than 75 mm are also available.
, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.