Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 225, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
-175 JA50-16-150 JA63-16-200 JA80-20-250 JA100-24-300 JA100-27-150 JA125-27-200 JA160-33-200 20 25 32 32, 40 40 32, 40 50 50, 63 80 100 100 125 160 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 M20 x 2.5 M24 x 3 M27 x 1.5 M27 x 2 M33 x 2 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000 28000 28000 71000 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000
1100 1100 1750 110 130 110 180 140 220 4700 4300 3450 2400 1950 1750 1750 1750 2750 2
80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
R410A(HFC) Quantity of refrigerant kg 0.72 0.74 Control method PID control Ambient temperature andhumidity and altitude 12 Temperature:5 to 40,Humidity:30 to 70%,Altitude: Less than 3000m Circulating fluid*3 Tap water, 15% ethylene glycol aqueous solution Operating temperature range1 5 to 35 Cooling capacity (50/60Hz) 4 W 4600/ 5100 4800/ 5800 Heating capacity (50/60Hz) 5 W 1000/ 1200 1100
1960 1650 3120 2800 5030 4540 7850 7150 12300 11300 15400 14400 20100 18800 25400 23900 31400 29500 49100 46300 70700 66800 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 314 264 491 412 804 691 1260 1100 1960 1650 3120 2800 5030 4540 7850 7150 12300 11300 15400 14400 20100 18800 25400 23900 31400 29500 49100 46300 70700 66800 8 20
1960 1650 3120 2800 5030 4540 7850 7150 12300 11300 15400 14400 20100 18800 25400 23900 31400 29500 49100 46300 70700 66800 314 264 491 412 804 691 1260 1100 1960 1650 3120 2800 5030 4540 7850 7150 12300 11300 15400 14400 20100 18800 25400 23900 31400 29500 49100 46300 70700 66800 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 8 20
Thomas Liquid Diaphragm Pump Flow Rate: 1100 ml / min , 1100 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 4.5 m H20 , 4.5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .73 lbs. / .33 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 1100 ml / min , 1100 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 4.5 m H20 , 4.5 m H20, Voltage (DC): 12, DC Motor Type: Low Cost, Net Weight: .51 lbs. / .23 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 1100 ml / min , 1100 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 4.5 m H20 , 4.5 m H20, Voltage (DC): 12, DC Motor Type: Standard, Net Weight: .49 lbs. / .22 Kg Series Configured Datasheet.
Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders
When using signal of the servo on (SON) by the I/O signal (CN6) . 0100 4 in HEX 0 0 in HEX 1100 C in HEX 0 0 in HEX When using signal of the Automatic/manual selection (MD0) by the I/O signal (CN6) 0001 1 in HEX 0 0 in HEX 1000 8 in HEX -44- * Enabling Servo-on (SON) and Automatic/manual selection (MD0) Signals Set PD12 to 0C04 and PD14 to 0801 in the I/O setting tab.
When using signal of the servo on (SON) by the I/O signal (CN6) . 0100 4 in HEX 0 0 in HEX 1100 C in HEX 0 0 in HEX When using signal of the Automatic/manual selection (MD0) by the I/O signal (CN6) 0001 1 in HEX 0 0 in HEX 1000 8 in HEX -49- * Enabling Servo-on (SON) and Automatic/manual selection (MD0) Signals Set PD12 to 0C04 and PD14 to 0801 in the I/O setting tab.