Fluct. l\,lax. +1% @ 79'F (25'C) {1A F.S.) Max. +2% @ 79'F (25'C) (1A F.S.) vEA 250 vEA 251 vEA 252 Cperating Temp.
SOLENOID SPECIFICATIONS Adder Number 0 1 Required Amplifier VEA1 30, VEA131 vEA 250, 251 ,252 Control Range 0-750mA 0 1 A Coil Resistance 26]2 (68"F (20"C) ) 1312 (68"F (20'C)) PorYer Consumotion 15W Max. Current (68"F (20"C) ) 13W Max. Current (68"F (20'C)) Insulation Class H Max. TempeEture Rise 284'F (140"C) at Full Current Elec-trical Connection DIN Connector (h" PF) NVEF.
(A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) q w e r q w e r N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Component Parts No.
With control unit Centralized wiring/Supply port left Individual wiring/Supply port right Centralized wiring air catch sensor ISA2-HE41P Terminal box Individual wiring air catch sensor 2 port solenoid valve 2 port solenoid valve ISA2-GE41 Regulator 3 0 3 0 3 0 3 0 3 0 3 0 Supply port Supply port P P P P P P T T T T T T U U U U U U E E E E E E L L L L L L S S S L L L S S S L L L 6 9 6 9 6
1 V 1.8 V 5 V Current output 4 mA 7.2 mA 20 mA (PF3W721-U30) A B C Voltage output 1 V 1.48 V 5 V Current output 4 mA 5.92 mA 20 mA Rated flow [L/min] Sensor model Minimum Maximum PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721-12/14 50 250 PF3W721-U30 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V Current output 2.4 mA 4 mA 20 mA 21.6
Fittings & Tubing Air Cylinders Rotary Actuators BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch a e White (PBT) b Switch holder d Auto switch mounting screw c Auto switch mounting band Band
'/s stl=0.44 300 (3") ]/s & 1/a st. 1/e &r/l st. 1/e & 1A st. 400 (4) 1/s &1/a st. r/s & 1/a st. 1/e &14 st. Series NCQT Dimensions Spring Extend NCQTBO-OT T Type Bore,, 9t4,F' I 60re ,b,:!
J F C X B + Stroke L Z M A + Stroke E T 2-P (Port size) I Q Metal connector 15.5 M14 x 1 A B C D E F G H I J K Bore size (mm) 32 40 50 63 Standard stroke 50, 75, 100, 125, 150, 175, 200, 250, 300 131 90 27 16 45 49.5 64 M14 x 1.5 14 4.5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200,
J F C X B + Stroke L Z M A + Stroke E T 2-P (Port size) I Q Metal connector 15.5 M14 x 1 A B C D E F G H I J K Bore size (mm) 32 40 50 63 Standard stroke 50, 75, 100, 125, 150, 175, 200, 250, 300 131 90 27 16 45 49.5 64 M14 x 1.5 14 4.5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200,
A--T.Tr/ir.{ 8r " 4 ' l e A . a ' A . , .
Positioning pin hole Counter-clockwise A port 5 Adjustment bolt A (For counter-clockwise rotation end adjustment) 95 22 .5 ge an Adjustment bolt B t r (For clockwise rotation end adjustment) en m e s st wi ju ck ad lo d -c B port en er Clockwise nt on Cl u o ti 0 o ad C ta se ck 19 ro wi ju wi k c st lo s C ge e m ro With Adjustment Bolt en an ta t r ti o n n r an e n d ge tio Size Adjustment
(For details, refer to page 4-4-25.) 4-4-20 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ500 Construction q e r t w y q e r t w y N.C. N.O.
M N C D 4-O T Q 2-P S U W E B K L AA A R X AB I AP Y + Stroke Z + Stroke J V 8-AF AC AD AE 100 piston rod end connection For standard strokes (mm) Bore size (mm) Stroke range (mm) AC G H AB AF AA AE AD F N M D L C K B J AP I A E 63 80 100 75, 100 125, 150 200, 250 300 15 20 depth 14.5 M16 x 2 depth 28 25 25 50 170 13.5 100 66 140 180 30 135 M12 x 1.75 depth 24 228 117 60 65 200 200 15 20
Heat exchanger Ventilation Circulating fluid Expansion E circuit valve A Expansion Inverter pump valve B E Temp. sensor (Ref. discharge Ball tap Fluid level gauge TS Press. sensor Over flow port (Ref. low press.)
Setup communication cable JX-CT-E *A set of the setup communication cable and USB cable. PC To e-Actuator (SingleLEC-W2-U) USB cable Communication Cable for Setting SingleJX-CTC-E Setup software (e-Actuator setup tool) e-Actuator setup tool USB driver Please download from SMC website. https://www.smcworld.com/ .
Locking type C (Manual) Rated voltage 4 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 2 3 3 position pressure center 4 0 1 0 1 5 24 VDC 12 VDC 6 9 5 Other Option Electrical entry Manual override/Non plug-in type Nil: Non-locking push type B: Locking type B (Slotted) C: Locking type C (Manual) Grommet L plug connector M plug connector DIN terminal L: With lead
When entry of part numbers becomes complicated, indicate on the manifold specification sheet. 580 A 5 Port Solenoid Valve/Plug-in Unit 10-SQ1000 Model Series Actuation type Model Response time (ms) Note 2) Weight (g) Standard (0.4 W) Quick response (0.95 W) Flow rate characteristics Note 1) Seal 1 4/2 (P A/B) 4 5 (A R1) b C [dm3/(sbar)] Cv b C [dm3/(sbar)] Cv Single 10-SQ1131 24 or less
5 w e r t @0 !4 !3 !8 !6!7 i q A A !1 !2 u @1 Section AA Parts list Material Note No. Description No.
(b) XLC50, 63, 80, 100, 160/ Air operated D E C E C E XLA Fn (KF flange) Fd (K flange) (a) XL XL XLQ (c) XM XY J DK XSA H B XVD A XGT G CYV A (mm) J A B C D E Note 1) Fn Fd G H K Model XLC-50 XLC-63 XLC-80 XLC-100 XLC-160 70 183 80 31 10.5 75 52 77 29 10.5 95 88 209 100 39 11 87 70 76.5 36 9 110 90 250 117 45.5 11 114 83 105 44 9 130 108 317.5 154 55 11 134 102 139 58 9 180 138 339 200 65
Z1K Z1L Z1M Z1W Z1N Z1P Z1Q Z1R Z1Y Z1S Z1T Z2K Z2L Z2M Z2N Z2P Z2Q Z2R Z2S Z2W Z2T Z3A Z3B Z3C Z3D Z3E Z3F Z3G Z3H Z3V Z3J A B C D E F H J K L M N Nil A B C D E F G H K L Z Nil XB A B D E H J L M Nil A B C D E F G H K L Z Nil XB A B C D E F G H J K L M N P Nil A B C D E F G H K L Z Nil XB A B C D E F M N P Q R S T U V W Y Z1A Z1B Z1C Z1U Z1D Z1E Z1K Z1L Z1M Z1W Z1N Z1P Z1Q Z1R Z1Y Z1S Z1T