(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M M9NWM 3 m L M9NWL 5 m Z M9NWZ 1
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.
In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B MHZ MHF Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.
Round plate (Including column) Position of rotational axis: Through the center axis (B) Number of teetha 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teethb 5.
Magnet: Built-in, Mounting: Rod Flange, Bore: 10mm, Stroke: 75mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Air Cushion, Series: J2
Magnet: Built-in, Mounting: Head Flange, Bore: 16mm, Stroke: 75mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Air Cushion, Series: J2
Magnet: Built-in Magnet, Series: J2W, Mounting: Basic Style, Bore Size: 10mm, Stroke: 75mm, Cushion: Air Cushion, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)