SMC Corporation of America
Elite Part Number Search
Search Results "CDA2KF63TN-150-M9PSAPC"

Mounting: Basic Style, Bore Size: 40mm, Thread: Rc, Stroke: 150mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 06mm, Suffix: Required Selection w/Speed Control

Mounting: Double Clevis, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 150mm, First Stroke: 100mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Foot, Bore Size: 32mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 150mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Foot, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 175mm, First Stroke: 150mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Foot, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 200mm, First Stroke: 150mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Rear Flange, Bore Size: 63mm, Thread: Rc, Full Stroke: 150mm, First Stroke: 50mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 150mm, First Stroke: 110mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Double Clevis, Bore Size: 63mm, Thread: Rc, Full Stroke: 150mm, First Stroke: 80mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 150mm, First Stroke: 50mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Foot, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 150mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: 50mm, Stroke: 150mm, Rod End Thread: Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket

Magnet: Built-in, Mounting: Foot, Bore Size: 32mm, Stroke: 150mm, Rod End Thread: Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Magnet: D (Built-in Magnet), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 125mm, Thread Type: TN (NPT), Stroke: 150mm, Option: Cushions at Both Ends, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in Magnet), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 140mm, Thread Type: TN (NPT), Stroke: 150mm, Option: Cushions at Both Ends, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Mounting: L (Foot), Bore Size: 50mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 150mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 20mm, Stroke: 150mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)