SMC Corporation of America
Elite Part Number Search
Search Results "AS2201FPG-01-06"

DIN (EN1753 01-803) terminal (A) 2 VP500 1 (P) 3 (R) External pilot N.C. 1/4 3/8 P. 8 8.8 Push-turn locking lever type (A) 2 1 (P) 3 (R) Conduit terminal VP700 X N.O.

VSA4120-02 VSA4120-03 VSA4220-01 VSA4220-02 VSA4220-03 VSA4320-01 VSA4320-02 VSA4320-03 VSA4420-01 VSA4420-02 VSA4420-03 2 position single VA 1 4 1 8 Rc 0.60 1 8 Rc 1 8 Rc SA 2 position double 1 4 1 8 Rc 0.70 1 8 Rc VA 1 8 Rc 3 position closed center 1 4 1 8 Rc 0.86 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200

-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -02-08 AS2200-02 100 200 50 100 0

Model Option 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Bracket assembly Note 1) AR50P-270AS Note 2) AR20P-270AS Note 3) Note 3) AR25P-270AS AR30P-270AS AR40P-270AS Set nut AR20P-260S AR25P-260S AR30P-260S AR40P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) 10: G49-4-01, 21: G49-4-01

Millimeter Inch With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 01 03 05 07 09 11 4 6 8 10 12 04 06 08 10 12 Thread _ Meter thread (M5) Unified thread (10-32 UNF) R(PT) N NPT Port size M5 X 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AS ASN AQ ASV Needle Valve/Flow Characteristics AK ASD230F ASD330F ASD430F ASS 100 200 400 1.5 6 3 07, 08, 09, 10, 11 Effective area (mm2) Flow

Metric size (Felease bushing: White color) s3.2, o4. a6, oB. o1o, o12 Inch size (Felease bushing:Orange color) 01 18 . 05132', o31 1 6', 01 14', 05116', o3l8 . a 1 2' Elbow fVpe/ln-line f}pe Minimizes installation time and cost Fittings and tubing are not necessary because this type screws directly into the actuator. Thus, piping labor and cost can be eliminated.

For details about applicable models, please contact SMC. 01 1 station Note 2) Note 3) The number of max. stations differs from kit to kit. (Refer to the table below.)

Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan

Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan

-01-06 VZM550-01-06S Toggle lever VZM550-01-08 PAT.

-01-06 VZM450-01-06S Toggle lever VZM450-01-08 VZM450-01-30R VM-30CR Red VM-30CB Black VZM450-01-30B Push button (Mushroom) VM-30CG Green VZM450-01-30G VM-30CY Yellow VZM450-01-30Y VZM450-01-32R VM-32CR Red VM-32CB Black VZM450-01-32B Push button (Extended) VM-32CG Green VZM450-01-32G VM-32CY Yellow VZM450-01-32Y With a set of red, black, green, yellow VM-33C Push button (Flush) VZM450-01

Type Type Elbow type straight type In-line type REA25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REA32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REA40 AS2201F-02-06-X214 AS2301F-02-06-X214 AS2001F-06-X214 REA50 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 REA63 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Table.

How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.

How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.

Conditions Body ported Tube bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 Series MB 6 x 1 m AS2301F-06 AN110-01 VZ5120-01 3-3-55 Series VZ5000 Construction 2 position single 2 position double De-energized De-energized 3 position closed center/exhaust center/pressure center 3 position closed center De-energized De-energized 3

0ol2,oV fiHz 11 = ilSOV 60Hz 49 = 12 VAC 50Hz 51 = 12 Y96 52 = 24 VDC 53 = ,r8 VDC Portlng m = Valve Only w/casket Set) NVS S24 01 = Mounted on Indivldual Subplate l/4'NPTF Slde Ports (5) 02 = Mounted on Indivldual Subplate 3/8' Hetf diae eorts 1q 03 = Mounted on Individual Subplate l/4" NFrF Bottom Ports (5) 06= Mounted on Indlvldual Subplale 1i4" NPTF Bottom Ports (5) & Side Ports (1) 21

Note) When ordering ejector without valve, select Nil for mounting. 04 KJH C2 Port size 04 06 03 07 !

Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Symbol 01 02 01 02 02 03 03 04 04 06 10 Body class LQ3 Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.