Model ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 Description Bracket B44P B44-1P : B45-1P 1: B45-2P B46P 3 4 Note) A float switch can not be mounted on ALT-5 or ALT-9 afterwards.
[inP] [inP][] [F20] GND 30 msec.
Model ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 Description Bracket B44P B44-1P : B45-1P 1: B45-2P B46P 3 4 Note) A float switch can not be mounted on ALT-5 or ALT-9 afterwards.
No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
Model ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 Description 3 4 Bracket B44P B44-1P : B45-1P 1: B45-2P B46P Note) A float switch can not be mounted on ALT-5 or ALT-9 afterwards.
Model ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 Description Bracket B44P B44-1P : B45-1P 1: B45-2P B46P 3 4 Note) A float switch can not be mounted on ALT-5 or ALT-9 afterwards.
) ASR430F-02-08S(-F20) ASR430F-02-10S(-F20) ASR530F-02-06S(-F20) ASR530F-02-08S(-F20) ASR530F-02-10S(-F20) ASR530F-02-12S(-F20) ASR530F-03-06S(-F20) ASR530F-03-08S(-F20) ASR530F-03-10S(-F20) ASR530F-03-12S(-F20) ASR630F-03-10S(-F20) ASR630F-03-12S(-F20) ASR630F-04-10S(-F20) ASR630F-04-12S(-F20) ASQ430F-02-06S(-F20) ASQ430F-02-08S(-F20) ASQ430F-02-10S(-F20) ASQ530F-02-06S(-F20) ASQ530F-02-
Foot style CS1-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 CS1-L30 Flange style CS1-F12 CS1-F14 CS1-F16 CS1-F18 CS1-F20 CS1-F25 CS1-F30 Single clevis style CS1-C12 CS1-C14 CS1-C16 CS1-C18 CS1-C20 CS1-C25 CS1-C30 Double clevis style CS1-D12 CS1-D14 CS1-D16 CS1-D18 CS1-D20 CS1-D25 CS1-D30 Order two foot brackets per cylinder.
Model ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 Description B44P B44-1P 1 : B45-1P 1 : B45-2P B46P 1 4 1 2 Bracket Note) A float switch can not be mounted on ALT-5 or ALT-9 afterwards.
[F20] Setting of external input is completed. -46No.PF-OMN0012-H [F22] Setting of analogue output This function can be used only when the optional analogue output is present. If the optional temperature sensor is fitted, the analogue output of fluid temperature can be selected.
[H_2] Hysteresis of OUT2 [ inP] External input 3 [REACUM] Accumulated flow external reset 25 50 100 [F20] Accumulated flow error Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) [F20] Setting of external input Accumulated flow external reset [F22] Setting of analogue output Free range analogue output for instantaneous flow: OFF * Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
(Refer to [F20] External input on page 47.) The name of the piping line where the product is installed can be displayed. (Refer to [F82] Line name on page 53.) The sub display can be turned off. -46No.PF-OMS0002-B [F20] External input This function is available when the model includes the external input function.
[F20] Setting of external input is completed. -50No.PF-OMM0005-N [F22] Setting of analogue output This function can be used only when the optional analogue output is present. If the optional temperature sensor is fitted, the analogue output of fluid temperature can be selected.
[inP] External input setting 5 [F20] [inP] [rAC] Accumulated value reset SET button Press this button to change to another mode and to set a value. [1-5] 1 to 5 V Voltage output (when voltage is output) [---] Analogue output is not selectable (for current type output) [F22] [AoUt] [AoUt] Analogue output setting 3 Displays the output status of OUT1 and OUT2.