Note) 20 Min. bending radius mm Min. bending radius mm 10 15 27 35 75 60 48 36 24 25 13 20 to 60C, With water: 0 to 40C (with no freezing) 100 20 to 60C, With water: 0 to 40C (with no freezing) Operating temperature Operating temperature Polyurethane Material Material Nylon 12 Note) Best Pneumatics No.4, page 2.4-1 Note) Best Pneumatics No.4, page 2.4-3 20m roll O.D. I.D.

Next, pour water at 5 to 40C, then measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104 . By substituting the measurement results for formula (8) to figure out Av.

Turbine oil P-32 Viscosity according to ISO Grade Classification of viscosity cst (40C) Classification of viscosity cst (40C) 32 32 Kyushu Oil Co. Stork Turbine 32 Nippon Oil Corp. Turbine oil 32/ Mitsubishi turbine 32 Showa Shell Sekiyu K.K. Turbine 32 Cosmo Oil Co., Ltd. Cosmo turbine 32 Tonen General Sekiyu K.K. General R turbine 32 Japan Energy Corp.

Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger.

The HAA can cool high temperature compressed air from compressors down to 40C or less while efficiently removing moisture from the air.? The series does not require cooling equipment, and is free from concerns such as water supply cut-off or freezing.?

MHZ2-40C, ACTUATOR, MHZ2 GRIPPER, PARALLEL, M1, 40MM MHZ2, 1.54880 lb

weight Output signal capacity Open drain output (Max.30 VDC or less, Max. 20 mA) Nominal size Basic weight Emergency stop, Output deviation, Power supply deviation, Driving deviation, Temperature deviation Stroke deviation, Motor deviation, Controller deviation Emergency detection items 16 2.24 0.14 0.01 General Specifications 25 3.95 0.21 0.02 How to calculate/Example: E-MY2C25-300TAN 5 to 40C

GXL-8F GXL-8FI GXL-8FB GXL-8FIB GXL-8FU GXL-8FUB N.O (A contact) N.C (B contact) AC servomotor (30w) Motor N.C (B contact) N.O (A contact) Lead screw Positioning repeatability Lead Speed Ball screw 8mm 0.03mm 2mm 50mm/s 10 (4)kg 5 (4)kg N.C (B contact) Refer to page 318 for detailed specifications of proximity switches. 5mm 100mm/s 10 (4)kg 5 (4)kg High rigidity direct acting guide 5 to 40C

Example) LXPBABC-100SB-F9N1F9G1-X12 Brake Home position switch Note 2) Without brake With brake Nil B None Yes (cable length 0.3m) Nil S Specifications Motor AC servomotor (30w) Lead screw Positioning repeatability Ball screw 8mm 0.03mm Lead Speed 2mm 50mm/s 5mm 100mm/s Horizontal Vertical 6kg 5kg 6kg 5kg Ball bushing 5 to 40C (with no condensation) Work load Guide type Operating temperature

Front matter 5 (4) Test method By attaching the equipment for testing with the test circuit shown in Fig. (3) and running water at 5 to 40C, measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104.

Fluid 5 to 40C (41 to 104F) Operating temperature C 0.2M to 1 x 10 -6 {1.5k to 7.5 x 10 -9} Operating pressure Pa {Torr} 5 8 5 8 Conductance l/s 1.3 x 10 -8 {1 x 10 -7} at ordinary temperatures, excluding gas permeation 1.3 x 10 -11 {1 x 10 -10} at ordinary temperatures, excluding gas permeation Internal External Leakage Pa m3/s {Torr l/s} KF16 KF25 KF16 KF25 Flange type/size Principle materials

Table of UL-compliant Products JSXD Series JSXZ Series JSXM Series Option Replacement Parts (4) Test method Connect the piece of test equipment to the test circuit as shown in Fig. (3), and run water at 5 to 40C.

LC1-1H2 Item 100/110V AC 10%, 50/60Hz (100V AC, 50/60Hz for LC1-1HV1) 200/220V AC 10%, 50/60Hz (200V AC 10% for LC1-1H32) (200V AC, 50/60Hz for LC1-1HV2) Power supply Leakage current 5mA or less Dimensions 80 x 120 x 244mm Weight 2.2kg Actuator control Item Model LC1-1H2H LC1-1H3H LC1-1H2V LC1-1H3V Compatible actuator model LTF6ELTF8FLTF6E-K LTF6E-K Motor capacity 200W 100W 200W 100W 5 to 40C

Temperature When operating at high temperatures (40C to 80C), there is danger of burns, etc. Confirm that the surface temperature of the filter or the parts for operation (V-band, element, etc.) are 40C or less, to prevent a burn from occurring. Warning Operation 1. Never loosen the V-band under pressurized conditions. 59

Temperature When operating at high temperatures (40C to 80C), there is danger of burns. Confirm that the surface temperature of the filter or the parts for operation are 40C or less, to prevent a burn from occurring. 531

Water Cooled Aftercooler Series HAW HAA HAW Series HAW can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. As series HAW is watercooled, it can be used where there is high temperature, high moisture and heavy foreign particles.

The base oil of grease in the cylinder may seep out of the tube, cover, crimped part or rod bushing depending on the operating conditions (ambient temperature 40C or more, pressurized condition, low frequency operation). 7.

Pour in 5 to 40C water and measure the flow rate with a pressure difference of 0.075 MPa. There are cases in which the pressure difference may need to be set higher in order to keep the Reynolds number in the range above 4 x 104 . Substitute the measurement results into the formula (8) to calculate Av.

(When using AF + AFM) This may be approximately 3000 hours with ultra-dry air (dew point 40C or equivalent). VEX SRH SRP Option SRF Part no.

Grease Grease-free R Clockwise L Counterclockwise Body material A2017 Weight (g) 12.5 49 114 206 310 * Air purification rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Low profile cyclone type 2A 3A Outer body diameter (mm) 20 25 Piping port size 1.6 Fluid Air* XT661 X260 2A R Operating pressure 0.01 to 0.5 MPa Proof pressure 0.75 MPa Ambient and operating temperature 5 to 40C