When tightening, do not hold the pressure switch body with a spanner. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
When and buttons are pressed and held simultaneously for 1 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
An injury or failure can result. 3 Step Setting Mode Maintenance Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
SET for 2 s or longer Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. 1. 1) OUT1 operation mode setting SET 1. 2) OUT1 output mode setting Troubleshooting Do not operate in an atmosphere containing flammable or explosive gases.
The output OUT1(1) set value input mode is selected. 1: The set value of P1 is -50 Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not use pressure sensors with corrosive and/or flammable gases. 7. The applicable fluids are air, non-corrosive gas and non-flammable gas. Consult with SMC if the switch is to be used with other types of fluids. Caution Connection Caution 1. Do not drop, bump, or apply excessive impacts (100 m/s2) while handling.
Do not attempt to rotate the connector, as it is not rotatable.
Do not apply negative pressure. It may result in malfunction. Should they remain, they could cause malfunction. 3. When connecting pipes and fittings, etc., be sure 3. Do not supply air pressure from ports other than that neither chips from the pipe threads nor sealing material get inside the valve.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Reset applied pressure to a level within the set pressure range.
Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bracket mounting Mount the bracket using the mounting screws supplied. The required tightening torque is 0.420.04 Nm.
The unit specification is displayed approx. 1 second Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Nominal thread size Required torque Rc (NPT)1/8 7 to 9 Nm System error. The internal circuit may be damaged. Do not use the product for flammable fluid. A fire or explosion can result. Only dry air, N2, CO2 and Ar are applicable.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not use the product for flammable fluid. A fire or explosion can result. Only air and N2 are applicable. Do not use the product in a place where static electricity is a problem.
Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. seconds, to display [F 0]. Select to display the function to be changed [F].
P_2 P_1 Instantaneous flow Set value or 3 4 Set value or 3 Excessive instantaneous flow Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Hysteresis 1 Hysteresis 1 L Flow has exceeded the upper limit of the display flow range. Reduce the flow.
Display accumulated flow Display instantaneous flow Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.