MPa) Outlet air set temperature Outlet air set temperature 68F (20C) 77F (25C) Air flow Air flow 10.6 scfm (300 L/min [ANR]) 17.7 scfm (500 L/min [ANR]) E E IDH4 or IDH6 are selected from Data .

Speed Controller Cylinder Solenoid valve Tubing Silencer Max. return speed (mm/s) 10 20 30 6 ASD230FM CJ2 SYJ500 TU0604 1 m AN11001 10 16 Cylinder size 20 ASD330FM CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 32 Values are measured at 0.5 MPa and 20C.

3/16" 1/4" 3/16", 1/4" 5/16" Tube O.D. 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 38 Flow rate l/min (ANR) Controlled flow 0.2 0.1 0.6 Effective area mm Flow direction symbols on body 230 180 100 460 260 390 Flow rate l/min (ANR) Meter-out type Meter-in type Free flow 3.5 2.7 1.5 7 4 6 Effective area mm Note) The flow rate value is at a pressure of 0.5MPa and temperature of 20C

Specifications Cleanliness class (ISO class) Class 3 Note 1) KPQ Series Brass (electroless nickel plated) Release button: Light gray Fluid Air Maximum operating pressure (20C) 1 MPa Note 2) Operating vacuum pressure 100 kPa Proof pressure (20C) 3 MPa 5C to 60C Ambient and fluid temperature Threads JIS B0203 (Taper thread for piping) Oil Fluorine-based grease Note 1) Refer to particle generation

Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.

Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" 1000 680 440 480 420 210 150 Flow rate l/min ANR (SCFM) INOUT (35.0) (23.8) (15.4) (16.8) (14.7) (7.35) (5.25) Effective area mmCv 15.2 10.4 6.7 7.3 6.4 3.2 2.3 (0.84) (0.58) (0.37) (0.41) (0.36) (0.18) (0.13) Note 1) Flow rate values are at a pressure of 0.5MPa (72 psi) and temperature of 20C (68F).

(Coil temperature: 20C, at rated voltage) 3-port (SX090) : Based on dynamic performance test, JIS B 8419.

Weight (kg) 0.9 Note) The non-lubricated specification is not applicable to these models. 0.9 1.0 1.4 1.4 Proportional Solenoid Specifications VEF3121 (Flow type) VEP3121 (Pressure type) Proportional solenoid recognition symbol 1 (Applicable power amplifier: VEA25 ) Applicable power amplifier VEA25 Max. current 1 A Coil resistance 13 (Ambient temperature 20C) Rated power consumption 13 W

E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +22C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.

, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow) Flow rate /min (ANR) 20 100 180 230 260 390 460 660 790 920 1580 1710 0.3 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Effective area (mm 2) Note 1) Flow rate values are measured at 0.5 MPa and 20C

12 10, 12 VCHC Controlled flow Free flow 230 100 260 390 460 660 790 920 1580 1710 Flow rate L/min (ANR) ASR ASQ Sonic conductance dm3/(sbar) 0.64 0.28 0.72 1.1 1.3 1.8 2.2 2.6 4.4 4.8 Flow Direction Symbols on Body Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C

AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C

0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7 250 0.94 340 1/8 90 0.7 250 0.94 340 1/4 115 2.3 810 2.3 810 1/4 130 2.3 810 2.3 810 3/8 124 0.2 4.6 1,670 4.6 1,670 1/4 221 0.35 4.6 1,670 4.6 1,670 3/8 214 4.6 1,670 4.6 1,670 1/2 205 7.9 2,840 7.9 2,840 1/4 242 11.9 4,270 11.9 4,270 3/8 233 11.9 4,270 11.9 4,270 1/2 224 Note) Flow rate values are measured at 0.5 Mpa and 20C

Metric sizes 6 8 10 12 Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 (free) flow Effective area mm 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.

frequency 1kHz Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light 10 to 55C Ambient temperature 25 to 70C Environmental resistance 45 to 85% RH Ambient humidity Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C

AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C

Metric size 4 4 6 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C.

AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 4 6 6 8 3.2, 4, 6 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C

operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5 MPa and 20C

12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C