SMC Corporation of America
Elite Part Number Search
Search Results "MHF2-12D1R-M9PS"

1 Auto Switch Series MHF2 Series MHF2 Auto Switch Installation Example and Mounting Position Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions. 1) Detection when Gripping Exterior of Workpiece Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions

1 Auto Switch Series MHF2 Series MHF2 Auto Switch Installation Example and Mounting Position Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions. 1) Detection when Gripping Exterior of Workpiece Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions

Body Option: Side Piping Type MHF2-DR Body option dimension table Unit: mm A B Model A C D B 25 MHF2-8DR 11 M3 x 0.5 37 5.5 MHF2-8D1R 61 MHF2-8D2R C 38 MHF2-12DR 14.8 M5 x 0.8 54 7 MHF2-12D1R 90 MHF2-12D2R 54 MHF2-16DR D D 19 M5 x 0.8 76 9 MHF2-16D1R (Finger closing port) (Finger opening port) 124 MHF2-16D2R 66 MHF2-20DR For dimensions not given above, please refer to the table of dimensions

DBL-ACT AUTO-SW, ACTUATOR, MHF2 GRIPPERS, GE, 16MM MHF2 DBL-ACT AUTO-SW, 1.21372 lb

Part Number Description: FINGER ASSEMBLY (MHF2-20D2)   Product Line: A   Product Line Description: ACTUATOR   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

Part Number Description: SEAL KIT, MHF2-8D2   Product Line: A   Product Line Description: ACTUATOR   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

Bore Size: 20mm, Symmetric Type: Standard, Stroke: 30mm, Adjuster: A (Both Sides Adjusters/Rubber Stoppers), Function: Standard, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Gripper ID: 16mm, Action: D (Double Acting), Rotation Angle: 90°, Switch at Gripper: N (No Switch), Gripper Sw. Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw. Lead Wire or Prewired Connector: 0.5m (Or None

Gripper ID: 10mm, Action: S (Single Acting (N.O.)), Rotation Angle: 180°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number Switch at Gripper: S (1 pc), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw. Lead Wire or Prewired Connector

Gripper ID: 16mm, Action: C (Single Acting (N.C.)), Rotation Angle: 90°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw

Gripper ID: 16mm, Action: S (Single Acting (N.O.)), Rotation Angle: 90°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw

Gripper ID: 16mm, Action: D (Double Acting), Rotation Angle: 90°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw. Lead

Gripper ID: 25mm, Action: D (Double Acting), Rotation Angle: 180°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw.

Gripper ID: 25mm, Action: D (Double Acting), Rotation Angle: 180°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw.

Gripper ID: 10mm, Action: D (Double Acting), Rotation Angle: 90°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number Switch at Gripper: S (1 pc), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw. Lead Wire or Prewired Connector: 0.5m

Gripper ID: 16mm, Action: D (Double Acting), Rotation Angle: 180°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw.

Gripper ID: 25mm, Action: C (Single Acting (N.C.)), Rotation Angle: 180°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation