System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE

Port Female Thread: C (with Pump System PE Port Female Thread), Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)

System: Q (Vacuum Pump System for Manifold), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port Female

PE Port Female Thread), Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type), Manifold Common Release Pressure Supply: P (Manifold Common Release Pressure Supply Spec.)

Port Female Thread: C (with Pump System PE Port Female Thread), Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: E (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type, Long Lock Nut)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port

Thread: C (with Pump System PE Port Female Thread), Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type), Manifold Common Release Pressure Supply: P (Manifold Common Release Pressure Supply Spec.)

Part Number Description: VALVE SOL   Product Line: V   Product Line Description: VALVE   Family Code: 285   Family Description: VSP4 SOL VALVE 4/5 PORT   Class Code: PE   Part Code: 1   Reference Code:  J   Click here to report information errorImage shown may not match exact part number, VALVE SOL, VALVE, VSP4 SOL VALVE 4/5 PORT, PE, VSP4 BASE MT 1/4, 3.52000 lb

Part Number Description: VALVE SOL   Product Line: V   Product Line Description: VALVE   Family Code: 285   Family Description: VSP4 SOL VALVE 4/5 PORT   Class Code: PE   Part Code: 1   Reference Code:  J   Click here to report information errorImage shown may not match exact part number, VALVE, SOL, VALVE, VSP4 SOL VALVE 4/5 PORT, PE, VSP4 BASE MT 1/4, 3.54576 lb

For the pilot EXH (PE) port When screwing piping or fittings into the valve, tighten them as follows. If the solenoid valve and the manifolds pilot EXH (PE) port is restricted extremely or blocked, abnormal operation of the solenoid valve may occur. 1) When using SMCs M3 or M5 fittings, follow the procedures below to tighten them.

Y DDIN N( 11 No.SY3000-OMH0002 SY series (SS5Y(3,5)-45(N)) 23, 43, 45, 45, 60DIN SY(3,5)245-FU DIN 2 A,B DIN T 25 2 610 3 1115 4 1620 5 A,B DIN DIN 23, 43 (SY9000) 8mm 45 (SY3000, 5000) 5.8mm 60 SY3000 4.7mm SY5000 5.8mm SY7000 8mm SY7000, SY9000 DIN DIN () SY7000, 9000 DIN SY3000, 60 5000 SY7000, 9000 DIN DIN 12 No.SY3000-OMH0002 SY series M8 M8 IP65 KJ SY (PE

) 12 VFR3000-OMJ0001-A No. 1(ISO VG 32) [3(EB),5(EA),PE] X(30.20.9MPa0.10.9MPa) 1. 2. 3. 4. 5. 6. 7. 13 VFR3000-OMJ0001-A Revision history A Renewal Qo 1st printing:JX 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of

VFR5100 A COM 5~60 () 3) VFR5200 A COM B Rc1/8 3 (kg) 0.83 A COM B VFR5 400 PA 44 38 32 (mm2) P1=0.7MPa;P2=0.5MPa S PB 38 40 31 5 AEA 90 (mm2) P2=0.5MPa S AEB 77 1) 0.9MPa 2) 3) .50 4) 2 5) P A B ARBF5000 ARBF5000 P A B 10 VFR5000-OMN0001 VFR5000 Series/ 01F D COM A B 01C COM A B 1)8 2)+COM -COM . 3)D U D 1)8 2)+COM -COM . 3)D U D 11 VFR5000-OMN0001 () X () [3(EB)4(EA) ] () (PE

Port (PE port) of pilot valve Foreign matter caught in pilot valve packing (6) Foreign matter caught in core Buzzing Abing continuous buzzing sound is emitted when the power is turned on. Worn coil (1) Low line voltage 11 VFR6000-OMA0001-B REMEDY No.

AC ( )() DC24V 16Nm 9 VFR6000-OMQ0001 VFR6000 Series/ / / / ) DIN DIN DIN DIN / / / / DIN 90 10 VFR6000-OMQ0001 () X () [3(EB)4(EA) ] () (PE) 11 VFR6000-OMQ0001 o. 1(ISO VG 32) [3(EB),5(EA),PE] X(30.2~0.9MPa0.1~0.9*MPa) 1. 2. 3. 4. 5. 6. 7. 12 VFR6000-OMQ0001 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com

(PE) port If the solenoid valves pilot EXH (PE) port is restricted extremely or blocked, abnormal operation of the solenoid valve may occur. sealing tape over the sealant before reusing. Do not use any form of sealant other than the tape type of sealant. (4) Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective.