Ratio of discharge amount to fresh water () 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPas) mPas Recommended typical condition B: Calculate discharge amount of fluid with viscosity 100mPas in case of discharge rate 4.5L/min and discharge pressure 0.1MPa. 1. Find ratio of discharge rate to fresh water for the fluid with viscosity 100mPas from the graph.
Ambient temperature 0 to 70 OC (No freezing or temperature fluctuation.) Pilot air pressure 0.2 to 0.5MPa Proof pressure 0.75MPa Mounting direction Horizontal (mounting hole at bottom) Weight 6kg Note 1) Above values are at room temperature and with fresh water.
Ratio of discharge amount to fresh water(%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity(mPa s) mPas Silicone oil Lubricant Vegetable oil Water 1 60 to 80 340 950 1500 3150 980 0 Viscosity (mPa s) 0 100 1000 10 Medical barium Cutting oil Tomato juice Honey Woosterource 4500 45 150 2000 to 3000 2650 8 - 8.
Additional symbols of the seal materials Seal material EPDM Barrel Perfluoro R Kalrez R Chemraz R VMQ FKM for PLASMA ULTIC ARMOR R Combination No. 2101-80 70W 4079 SS592 SS630 SSE38 1232-70 3310-75 UA4640 Symbol -XN1 -XP1 -XQ1 -XR1 -XR2 -XR3 -XS1 -XT1 -XU1 Note1) Due to the different materials used, changing only the seal may prove inadequate.
O ring O ring Pipe O ring O ring 70 8-6-5. Assembly of the Air cylinder parts (1) Mount the head cover to the cylinder tube. Head cover Cylinder tube (2) Mount the piston assembly to the cylinder tube. Mount the sensor rod inserting it to the piston rod hole. Be careful not to bend or hit the sensor rod. Take care not to scratch the piston seal during mounting.
Click Monitor Graph of Setup software to display Graph window. 70 - 5.11.1 Under the setting Tab: Setting of the items to display the graph Set the items to display analogue and digital waveform, trigger conditions and time for the Horizontal axis of the graph.
10 55 60 D-M9V-900 1 D-M9WV-900 55 30 (n 4 65 30 (n 4 60 30 (n 4 70 30 (n 4 10 30 (n n=(4,8,12,16) n n=(4,8,12,16) n=(4,8,12,16) n=(4,8,12,16) n=(2,4,6,8) 15 Auto switch Connection and Example 16 3.
The pushing force values for Battery-less absolute (Step motor 24 VDC) / Size 2530 to 50, Size 3230 to 70, Size 4020 to 45. The pushihng force values change according to the duty ratio and pusing speed.
Position 000 123.45mm 001 234.56mm 70 - Selection of the direct input. After selecting Direct with key, press the SET key. AX IS. AX IS. Step 1 Step 1 Position No. Position 123.45mm 000 123.45mm Acceleration 001 234.56mm Press the key twice. Press the key twice. AX IS. AX IS. Step 1 Step 1 Position No.
The value to express 700.00mm is 70, and 00011170h in hexadecimal. When 00 01 11 70 h is input to the register, please do as following.
VXF21A VXF22A VXF23A VXF24A VXF27B VXF28B VXF25(A,B) VXF26(A,B, C,D) Product number Orifice size mm 22 28 44 53 70 80 90 100 Air Fluid Minimum operating pressure Maximum operating pressure MPa 0.03 0.1 MPa 0.7 Fluid temperature -10 (Non-freezing) to 60 Ambient temperature -10 to 60 Coil insulation type Class B Enclosure IP65 Alloable voltage fiuctuation 10% of rated voltage AC VA 10 7
function Short circuit protection 12 bit Resolution 0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA Input signal range 16 bit Resolution -10 to 10 V, -5 to 5 V -20 to 20 mA Max. rated input signal 15 V 40 mA Input impedance 100 k 50 Linearity (25 oC) 0.05%F.S or less Repeatability (25 oC) 0.15%F.S. or less Absolute accuracy (25 oC) 0.5%F.S. or less 0.6%F.S. or less Current consumption 70
Installation 20 Installation 20 Model Indication and How to Order 23 Summary of Product Parts 24 Connector (Base only) 25 LED Display 26 LED indication of base 26 LED indication of remote 28 Setting and Adjustment 29 Setting 30 Dimensions 46 I/O Map 48 I/O mapping 49 I/O mapping order of base/remote 50 Diagnostic allocation 56 Detailed diagnostic data 57 Specifications 64 Troubleshooting 70
Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g -12No.LV50***-OMQ0004-F Summary of product parts Body With lead wire and M12 connector (4 pins) (Options) Connector Piping port (OUT side) Piping port (IN side) Bracket (Options) Description Function Connector The part to which lead wires are connected.
Forgotten the security code 70 Troubleshooting 71 Specifications 79 Dimensions 81 -1No.PS-OMW0005-C Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Maximum load for horizontal mounting: 70% or less of the holding force (Maximum static load) for spring lock Selection Maximum load for vertical mounting: 35% or less of the holding force (Maximum static load) for spring lock Warning 1. Confirm the specifications.
(Port size) Semi-standard specifications With element service indicator Clearance for maintenance Optional specifications With auto Standard specifications Model Bracket mount drain P A B C D E G J M N Q R S T U V B AFM20-D 1/8, 1/4 40 87.6 17.5 21 45 21 30 27 22 5.4 8.4 60 2.3 28 104.9 AFM30-D 1/4, 3/8 53 115.4 21.5 26.5 30 50 26.5 41 35 25 6.5 13 71 2.3 32 157.1 AFM40-D 1/4, 3/8, 1/2 70
Refer to the straight inlet piping length and accuracy graph (page 70). Avoid sudden changes in the piping size on the IN side of the product. Do not release the OUT side piping port of the product directly to the atmosphere without the piping connected. If the product is used with the piping port released to atmosphere, the accuracy may vary.
(Set value LEY25S/32S15 to 30%) (Set value LEY63S 15 to 50%) (Set value LEY25T/32T12 to 24%) (Set value LEY63T 12 to 40%) 1003 65 127 242 79 154 294 98 192 385 368 156 304 573 131 255 485 157 308 588 197 736 521 1012 1910 3343 Actuator specifications to 300 900 450 225 1200 600 300 1000 500 250 1000 500 250 305 to 400 600 300 150 Maximum Speed Range 405 to 500 800 400 200 640 320 160 of 70
dust and powder Location that is exposed to corrosive gas, solvent, and flammable gas Location that is exposed to direct sun light or radiant heat Location where ambient temperature is out of the following range: In operation 10 to 35C In storage 0 to 50C (with no water or circulating fluid in piping) Location where relative humidity is out of the following range: In operation 30 to 70%