Applicable FluidsP11 8.Fittings and Special ToolsP12 9.Failure and countermeasuresP13 1 2 3 4 5 6 7 8 9 10 11 12 13 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2019 SMC Corporation
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: E (N.O. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE/SOL, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
Series CRB2-Z, single or double vane, rotary actuator is availbable in 10, 15, 20, 30 and 40 bore. The single vane style use specially designed seals and stoppers which enable this compact type actuator to rotate up to 270 degrees.
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE/SOL, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE/SOL, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
Series CRB2-Z, single or double vane, rotary actuator is availbable in 10, 15, 20, 30 and 40 bore. The single vane style use specially designed seals and stoppers which enable this compact type actuator to rotate up to 270 degrees.
Stations: 10 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: without Option, Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: C [Vacuum Pump System PE Port Female Thread Specification (M3)], 1st
Setting method Ex) In case that setting pressure is 0.3MPa on ITV2030(0.5MPa specification). (0.3MPa/0.5MPa) 1023 = 614 (Decimal) Binary data of 614( Decimal) is 10 0110 0110.
Type: Bottom Mount / Compact / Mount-Type Pressure Gauge, Maximum Indicated Pressure(Mpa): 0.01, Connection screw: Female thread (M5 × 0.8), Option: None, Indicated Pressure Range: -101 to 10 kPa, Pressure Specifications: For vacuum, Applicable Tube Size: -, Unit Specifications: With unit conversion function
Type: -, Maximum Indicated Pressure(Mpa): -, Connection screw: Single-action fittings, Option: With case holder (PPA-B), Indicated Pressure Range: -101 to 10 kPa, Pressure Specifications: For vacuum, Applicable Tube Size: ø4, Unit Specifications: With unit conversion function
Type: Bottom Mount / Compact / Mount-Type Pressure Gauge, Maximum Indicated Pressure(Mpa): 0.01, Connection screw: Single-action fittings, Option: None, Indicated Pressure Range: -101 to 10 kPa, Pressure Specifications: For vacuum, Applicable Tube Size: ø6, Unit Specifications: With unit conversion function
Type: Bottom Mount / Compact / Mount-Type Pressure Gauge, Maximum Indicated Pressure(Mpa): 0.01, Connection screw: Single-action fittings, Option: With case holder (PPA-B), Indicated Pressure Range: -101 to 10 kPa, Pressure Specifications: For vacuum, Applicable Tube Size: ø6, Unit Specifications: With unit conversion function
Type: -, Maximum Indicated Pressure(Mpa): -, Connection screw: Single-action fittings, Option: With case holder (PPA-B), Indicated Pressure Range: -101 to 10 kPa, Pressure Specifications: For vacuum, Applicable Tube Size: ø6, Unit Specifications: SI unit fixed
Type: -, Maximum Indicated Pressure(Mpa): -, Connection screw: Female thread (M5 × 0.8), Option: With case holder (PPA-B), Indicated Pressure Range: -101 to 10 kPa, Pressure Specifications: For vacuum, Applicable Tube Size: -, Unit Specifications: With unit conversion function
, Pipe Connection Direction: [Down] Down, Connecting Tube Diameter: -, Display: No, Lamp: No, Acquired Standards: CE, Protection Structure: IP40, Application: Negative pressure [0 to −101 kPa], Option: Without connector, Analog Voltage Output(V): 1 to 5 V DC, Accuracy(%F.S.): ±2, Female thread compatible: With M5 female thread
, Pipe Connection Direction: [Down] Down, Connecting Tube Diameter: -, Display: No, Lamp: No, Acquired Standards: CE, Protection Structure: IP40, Application: Negative pressure [0 to −101 kPa], Option: Without connector, Analog Voltage Output(V): 1 to 5 V DC, Accuracy(%F.S.): ±2, Female thread compatible: -
, Pipe Connection Direction: [Down] Down, Connecting Tube Diameter: -, Liquid contact parts material: [Stainless Steel] 304 Stainless Steel, Mounting Hole: No, Display: No, Lamp: No, Acquired Standards: CE, Protection Structure: IP40, Application: For vacuum pressure [0 to -101 kPa], Option: None, Analog Voltage Output(V): 1 to 5 V DC
Specification: Voltage, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): 0~50, Operating Humidity Range(%): 35~85, Number of Inputs: 1, Number of Outputs: 1, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%
, Pipe Connection Direction: [Down] Down, Connecting Tube Diameter: -, Liquid contact parts material: [Stainless Steel] 304 Stainless Steel, Mounting Hole: No, Display: No, Lamp: No, Acquired Standards: CE, Protection Structure: IP40, Application: For vacuum pressure [0 to -101 kPa], Option: Sensor cable (3 m), Analog Voltage Output(V): 1 to 5 V DC