Port Size: 2 (25A), Piping: A (Direct Piping Type), Material: A (NBR/POM, w/o Silencer, Normal Temperature), Voltage Electrical Entry: Z (other Voltages), Other Voltages and Electrical Options: 1G (220 VAC, DIN Terminal w/Surge Voltage Suppressor), Thread: B (NPT)
Port Size: 3 (40A), Piping: A (Direct Piping Type), Material: A (NBR/POM, w/o Silencer, Normal Temperature), Voltage Electrical Entry: Z (other Voltages), Other Voltages and Electrical Options: 1G (220 VAC, DIN Terminal w/Surge Voltage Suppressor), Thread: B (NPT)
Port Size: 3 (40A), Piping: A (Direct Piping Type), Material: A (NBR/POM, w/o Silencer, Normal Temperature), Voltage Electrical Entry: Z (other Voltages), Other Voltages and Electrical Options: 2G (220 VAC, DIN Terminal w/Surge Voltage Suppressor, w/Light)
Port Size: 2 (25A), Piping: A (Direct Piping Type), Material: C (FKM/PTFE, w/o Silencer, High Temperature), Voltage Electrical Entry: Z (other Voltages), Other Voltages and Electrical Options: 1Q (220 VAC, Conduit w/Surge Voltage Suppressor), Thread: B (NPT)
Port Size: 4 (50A), Piping: A (Direct Piping Type), Material: A (NBR/POM, w/o Silencer, Normal Temperature), Voltage Electrical Entry: Z (other Voltages), Other Voltages and Electrical Options: 2G (220 VAC, DIN Terminal w/Surge Voltage Suppressor, w/Light)
Port Size: 2 (25A), Piping: A (Direct Piping Type), Material: A (NBR/POM, w/o Silencer, Normal Temperature), Voltage Electrical Entry: Z (other Voltages), Other Voltages and Electrical Options: 2G (220 VAC, DIN Terminal w/Surge Voltage Suppressor, w/Light)
.: 25), Voltage/Electrical Entry: Z (Other Voltages), Other Voltages and Electrical Options: 1B (220 VAC; Grommet w/Surge Voltage Suppressor, Special Voltage)
.: 10), Voltage/Electrical Entry: Z (Other Voltages), Other Voltages and Electrical Options: 1B (220 VAC; Grommet w/Surge Voltage Suppressor, Special Voltage)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: N (NPT)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: F (G)
Rated, 24 VDC: 20.4 VDC to 26.4 VDC
Rated, 100 VAC: 85 VAC to 110 VAC
Rated, 200 VAC: 170 VAC to 220 VAC
Body Type: O (For Manifold), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 4 (220 VAC, 50/60 Hz, Semi-Standard), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 4 (220 VAC, 50/60 Hz, Semi-Standard), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)]
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 4 (220 VAC, 50/60 Hz, Semi-Standard), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: None, Port Size: 01 [1/8 (6A)]
.: 15, Voltage/Electrical Entry: Other Voltages, Other Voltages and Electrical Options: 220 VAC; Conduit Terminal w/Surge Voltage Suppressor, w/Light, Other Options: -
Size: Series 20, Flow Type: None, Body Material: Brass, Seal Material: FKM, Orifice Diameter/Port Size: Orifice Diameter: ΓΈ3.2mm; Port Size: 1/4, Thread Type: Rc, Rated Voltage: 220 VAC, Electrical Entry: Conduit, w/Surge Voltage Suppressor, Oil-free Option: -, Bracket: -