SMC Corporation of America
Elite Part Number Search
Search Results "LVM20R3Y-5A-Q"

Function 1: 2 Position Single, Seal Type: Rubber Seal, Function 2: Standard (1W DC, AC), Voltage: 110VAC 50/60HZ, Lead Wire: L Plug Connector w/Lead Wire 0.3m, Manual Override: Locking Lever Style, Port Size: 1/4" One-touch Fitting, Q: Q (CE Marked)

Function 1: 2 Position Single, Seal Type: Metal Seal, Function 2: Standard (1W DC, AC), Voltage: 24VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Manual Override: Non-locking Push Style, Port Size: ø6 One-touch Fitting, Q: Q (CE Marked)

Function 1: 2 Position Double, Latching, Seal Type: Rubber Seal, Function 2: -COM, Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Manual Override: Non-locking Push Style, Port Size: ø8 One-touch Fitting, Q: Q (CE Marked)

Function 1: 2 Position Single, Seal Type: Metal Seal, Function 2: -COM, Voltage: 24VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Manual Override: Non-locking Push Style, Port Size: ø6 One-touch Fitting, Q: Q (CE Marked)

Function 1: 2 Position Single, Seal Type: Rubber Seal, Function 2: Standard (1W DC, AC), Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Manual Override: Non-locking Push Style, Port Size: 5/32" One-touch Fitting, Q: Q (CE Marked)

Function 1: 2 Position Single, Seal Type: Rubber Seal, Function 2: Standard (1W DC, AC), Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Manual Override: Non-locking Push Style, Port Size: 5/16" One-touch Fitting, Q: Q (CE Marked)

(Pattern for 3 digits on the right) Characters Q, X, Z, /, or cannot be displayed. (Pattern for 1 digit on the left) Characters A to Z can be displayed (the same as the 3 digits on the right). Display OFF The Sub display is not displayed. -43No.PS-OMV0004-H [F11] Display resolution setting This function is to change the pressure display resolution.

(Pattern for 3 digits on the right) Characters Q, X, Z, /, or cannot be displayed. (Pattern for 1 digit on the left) Characters A to Z can be displayed (the same as the 3 digits on the right). Display OFF The Sub display is not displayed. -46No.PS-OMV0009-E [F11] Display resolution setting This function is to change the pressure display resolution.

LX2007. 10 SYM BO L J K L M N o P Q R S T U Year 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 SYM BO L o P Q R S T U V W X y Z M ont h J an Feb M ar Apr M ay J un J ul Aug Sep O ct N ov D ec 4-

Power supply ON/Servo OFF: Green flashes. q q PWR Power supply LED y w With alarm : Red turns on. Parameter setting : Red flashes. w ALM Alarm LED Change and protection of the mode switch (Close the cover after changing switch.) u i e Cover o !0 Frame ground (Tighten the bolt with the nut when mounting the controller. Connect the ground wire.) r FG !1 !2 t y u i o !0 !1 !2 !3 !4 !5 !

6ON/OFF valve for oil mist 190 190 t y q t y q 6 6 !0Supply pressure gauge !0Supply pressure gauge R3.5 R3.5 OIL, AIR OIL, AIR Rc1/4 Rc1/4 L L K K C C O O AIR BLOW SUP SUP !1Tank pressure gauge !1Tank pressure gauge 272 272 153 238 153 238 e e 189.5 153 2 189.5 2 u u w r i w r i o o Material Note Main Parts List Part no. Spare Parts/Replacement Parts Part No. No. Description No. Qty.

Grease 10 g GR-S-010 qPiston seal wRod seal eTube gasket CQ2B32-PS Seal kit includes q, w, e. Since the seal kit does not include a grease pack, order the Grease Pack separately. 184

Grease 10 g GR-S-010 qPiston seal wRod seal eBumper MUB32-PS Seal kit includes q, w, e. Since the seal kit does not include a grease pack, order the Grease Pack separately. 185

Calculation method of volume ratio (Kv value) Necessary effective length = Basic condition length L x Correction factor C1 x C2 x C3 Calculate the piping volume Vt and the actuator volume Vc and substitute them into equation q below.

./0.05 MPa Ambient and fluid temperature 5C to 60C Port size Rc1/4 (Gauge port Rc1/8) Weight Approx. 700 g (at 100 mm stroke) Construction/Principle of Operation When signal pressure enters input chamber q, the input diaphragm e is deflected left. Clearance of the nozzle y is reduced causing higher back pressure at diaphragm A u.

Rc1/8 ISA-12-A G1/8 ISA-12-C q Joint screws (2 pcs.) ISA-161 e Threaded plug with seal ISA-12*1: Spacers are included for 4 and 6 stations. Bracket ISA-14 DIN rail ISA-5-m L Stations Part no.

Static Neutralization Characteristics (Discharge Time from 1000 V to 100 V) q Energy saving static neutralization nozzle with right angles: IZN10-01-X367 wHigh flow rate nozzle with right angles: IZN10-02-X367 5 5 0.1 MPa 0.05 MPa 0.3 MPa 0.1 MPa 0.05 MPa Discharge time (Static neutralization time) [s] Discharge time (Static neutralization time) [s] 4 4 3 3 0.3 MPa 0.7 MPa 2 2 0.5 MPa 0.5

0 o i u y t r e w q No. Description Type Contents Power supply indicator Illuminates when power is supplied. Flashes when the supply voltage is irregular. 1 LED (Dark green) Sensor indicator 2 Illuminates when the feedback sensor, autobalance sensor [high-precision type], or autobalance sensor [body-mounting type] is connected.

With one-touch fitting Construction q w e r t y o u i !0 KK130P KK130S q !1 !1 !2 !2 Plug Socket Figure: Connected plug and socket Plug Socket No. Description Material Note Description Material Socket body Sleeve Valve Main body Sleeve spring Valve spring Holder Plug O-ring Seal Steel ball Cassette Seal Note No.

D1 Protection diode D2 Surge supressor (Surge absorbing diode) D3 Surge supressor (Surge absorbing diode) Tr Output transistor Example of wiring Relay, example of wiring for resistant load, etc q SET: Push button w ALM: Alarm LED (Red) SMC DIGITAL PRESSURE SENSOR Vcc D1 Brown (+) ALM.