GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .42683 lb
(No freezing) Ambient temperature 0 to 60 C (No freezing) Maximum viscosity 5000 mPas Weight (kg) 3.0kg Mounting orientation Horizontal (with mounting foot at bottom) Packaging General environment These are reference values given for rated temperature and tap water and are not guaranteed.
If the total lifting height is required instead of the discharge pressure, a discharge pressure of 0.1 MPa corresponds to a total lift of 10 m. Selection procedures: 1. First mark the intersection point for a discharge rate of 15 L/min and a discharge pressure of 0.14 MPa. 2. Find the pilot air pressure for the marked point.
Construction and Outer dimensions 1 Atm , vent port Bonnet assembly (maintenance part) (inc. each part excluding body, external seal and accessory) Bonnet (material A6063) 6 External seal (maintenance part) 3 Vacuum pump side Valve seal (maintenance part) 2 Valve (material SUS304) 5 Body (material A6063) 4 Chamber side E C A A B D Dimensions [mm] Model A B C D E XLJ-25 50 139 111 48 44 (54
Electrical entry Grommet Lead wire Vinyl sheath cable 4.8, 0.5 mm2, 2-wire Impact proof 1000 m / s2 Insulation resistance 50 M or more under the test voltage 500 VDC (between case and cable) Withstand voltage 1000 VAC 1min (between case and cable) Ambient temperature -10 to 60 C Enclosure IEC60529 criteria IP67 Standards CE, UL, RoHS Magnetic field resistance When the alternative welding
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows. Should be 3% or less of rated voltage. 3.
ITV2-OM00109-C P R O D U C T N A M E E/P Regulator (16points preset input type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-52* Series (Switch output: NPN output) ITV1000/2000/3000/2090-53* Series (Switch output: PNP output) Install and operate the product only after reading the Operation Manual carefully and understanding its contents.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. DC coil 3% or less of the rated voltage 6.
40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.
106 2 2.3 3.2 6 7 10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 108 155 221 13 16 19 20 22 25 1/4, 3/8 3/8, 1/2 1/2, 3/4 1in = 25.4mm 5 Series AMP Model Selection Selection Caution Caution 1.
Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
C A 1(P) 2(A) Air Supply Warning B 1 Mount air filter to supply side close to valve. Filtration rating has to be 5m or smaller. 3(R) Model VHS2500 VHS3500 VHS4500 VHS5500 A 60 78 85 136 B 20 29 32 56 C 12.8 12.8 12.6 32 D 40 53 70 90 E 44 53 64 80 F 33 42 49 65 G 28 29 36 54 H 7.5 7.5 10 10 3.6-18
Operating Pressure Max operating pressure (MPa) 40C 0.65 60C 0.5 Applicable fittings One-touch fittings 5 Max. operating pressure (MPa) Min. bending radius (mm) 18 24 30 36 10 4 Operating temperature 20 to 60C Material Polyurethane 3 How to Order 2 1 TUH0644 B 20 0 -20 0 20 40 60 Operating temperature (C) Length per roll Tubing model Length 20 m roll 100 m roll Symbol 20 100 Precautions Be
3/4 & 1 128 161 59 77 74 64 (Max. 73) AVL5000-*06 to 10-*DZM 3/4 & 1 128 161 59 77 34 74 64 (Max. 73) Soft start valve with lock out H Air direction Nil Left to Right C E D F Port thread Rc Body size R Right to Left Nil 20 1/4 N NPT 30 3/8 F G 40 1/2 50 3/4, 1 Electric entry 1(P) 2(A) Port size Manual lockout Nil 1/4 (AVL2000) 02 D type DIN connector D Rated coil voltage 3/8 (AVL3000)
Voltage Symbol Voltage Applicable size 1E 2E 3E 4E 6E 8E 11E 15E1 10 Single-phase 100 VAC (50Hz) 100/110 VAC (60Hz) V V V V V V V V 20 Single-phase 200 VAC (50Hz) 200/220 VAC (60Hz) V V V V V V Options Symbol 1 Nil A C G K L M R S T Power supply terminal block connection (Voltage symbol 10 only) 3 With a terminal block for power supply, operating, and error signals 4 With an earth leakage
Port thread type 80 80 mm Rc Nil 100 100 mm Table position detector hardware TN NPT Position detector arms Switch bracket Positioning angle Symbol TF G Table unit/ Auto switch a b c d 10 11 12 13 14 15 20 23 25 180 c Nil Without auto switch (Built-in magnet) Stroke (mm) 90 Refer to Standard Stroke on page 452.
Coolant Valve Series SGC Made to Order Made to order specifications (For details, refer to page 389) How to Order External pilot solenoid 2 2 Y 1 A 1 T Z 10 A 05 SGC Air operated 2 2 1 A A 05 10 SGCA q w e r t y u i o !0 !1 !2 !3 !4 !
106 2 2.3 3.2 6 7 10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 108 155 221 13 16 19 20 22 25 1/4, 3/8 3/8, 1/2 1/2, 3/4 1in = 25.4mm 5 Series AMP Model Selection Selection Caution Caution 1.
Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
(mm) 10 9 8 7 6 5 4 3 Manifold stations n L1 L2 2 180 165 150 135 120 105 90 75 60 235.5 223 198 185.5 173 160.5 148 123 110.5 8