30 50 53 112 16 28.5 38 12 21 60 M6 X 1 35 32 161 Rc(PT)1/8 50 82 105 37 80 25 60 63 132 20 47 33 12 25 70 M8 X 1.25 40 38 188 Rc(PT)1/8 60 92 125 44 95 20 70 73 162 25 58 82.5 40.5 14 26 M8 X 1.25 45 50 241 Rc(PT)1/8 75 104 150 55 115 20 Without rear plate Long stroke Bracket mounting stroke Bracket mounting stroke Stroke range (mm) Bore (mm) Bore (mm) Bore (mm) Y R Z 20 25 32 40 50 20
0.1 0.1 5 L L 0 20 30 50 60 Holding point L (mm) 40 70 0 30 40 60 70 Holding point L (mm) 50 80 90 2.8-4 180 Angular Gripper Series MHY2/MHW2 MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7MPa Pressure 0.7MPa Pressure 0.7MPa 250 20 0.6 80 0.6 0.6 Holding force (N) Holding force (N) Holding force (N) 200 0.5 0.5 0.5 60 15 0.4 0.3 150 0.4 0.4 40 10 0.3 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40
40 7 7 9 M5 X 0.8 M8 X 1.25 20 32 31 60 95 60 12 63 125 132 103 1/8 Rc(PT) 70 40 7 7 9 M8 X 1.25 20 32 38 60 95 125 60 12 132 63 104 1/8 Rc(PT) 45 8 8 11 M8 X 1.25 25 38 47 70 75 12 73 150 162 115 82.5 115 Bore size (mm) Y WH Wq X Z 20 25 32 40 23 30 30 146 182 25 30 37 167 199 25 37 167 202 28.5 20 44 210 227 33 Without rear plate Long stroke Stroke range (mm) Bore size (mm) Bore size (
Material of body and guide block is martensitic stainless steel. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Stroke adjuster 10 Three types (rubber stopper, metal stopper, shock absorber) are available. 20 With shock absorber 30 40 50 60 70 80 90 Auto switch attachable Highly flexible piping methods 100 Switch rail and magnet (Standard) Without switch rail and magnet
-75kPa -80kPa -85kPa 100 Pad diameter (mm) 80 63 50 40 10 30 50 70 100 200 5 7 Lifting force (N) How to read Example: Work load 20 kg (Lifting force: 196 N) Conditions:Desired number of pads 5 pcs.
30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 658 180 Angular Style Air Gripper Series MHY2/MHW2 MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 200 0.5 0.5 0.5 60 15 0.4 0.3 0.4 150 0.4 40 0.3 10 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40 Gripping
D PNP open collector 2 output + Analog output 70 PNP open collector 2 output + Auto shift input Optional Note) Auto shift input is used for the auto shift function. For more information, please refer to Auto Shift Function on page 5.
D PNP open collector 2 output + Analog output 70 PNP open collector 2 output + Auto shift input Option Note) Auto shift input is used for the auto shift function. For more information, please refer to Auto Shift Function on page 16-2-32.
70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
50 188 52 126 178 215.5 40.5 95 70 238 77 151 228 265.5 43 120 90 288 102 176 278 315.5 D-X Individual -X 505 Series CXWL 10 With End Lock: CXWL10Stroke/25 to 100 R Max.
14 2.8 depth 8.4 PF2M711/721-02(-L) 70 17 2.8 depth 6.2 PF2M711/721-N2(-L) 70 17 2.8 depth 6.2 PF2M711/721-F2(-L) 78 21 2.8 depth 6.2 -101No.PF-OMW0007-E PF2M7#L-#1/2(-L) (mm) Model A C B P PF2M701/702/705/710/725/750L-01(-L) 84.4 11 14 2.8 depth 8.4 PF2M701/702/705/710/725/750L-N1(-L) 84.4 12 14 2.8 depth 8.4 PF2M701/702/705/710/725/750L-F1(-L) 84.4 13 14 2.8 depth 8.4 PF2M711/721L-01(-
With attachment plug lead wire: VV5FS2-01W1Station Port size Electrical entry Pilot EXH port 1(P), 3(R2), 5(R1) port Insert plug with lead wire Lead wire length L = 1000 Indicator light Push type manual override 158 (3 position) 150.5 (Double) 101 (Single) External pilot port Station Bottom ported: VV5FS2-01W2-01 Stations U side D side 2(B), 4(A) port n: Stations 1 70 81 2 95 106 3 120 131
70 Note) The L dimension of 2 to 6 stations is the same.
A 70 AERSBAN-ESET 70 56 clamp B: 1pc. B 45 11 27 11. OPTIONS AND AUXILIARY EQUIPMENT (d) Line noise filter (FR-BSF01, FR-BLF(Mitsubishi Electric Corporation)) This filter is effective in suppressing noises radiated from the power supply side and output side of the driver and also in suppressing high-frequency leakage current (zero-phase current) especially within 0.5MHz to 5MHz band.
Pin description 1 DC(+) PF2W740 2 OUT2 3 DC() 120 60 1.6 17 67 6 4 OUT1 FLOW SWITCH U P 34 55 S E T 60 50 34 OUT1 OUT2 DOWN FOR WATER 34 2-Port size 4-4.5 50 40 (42.2) 73 34 Flow direction 20 Series PF2W Dimensions: Integrated Display Type for Water PF2W711 148 77 80 79 32 9 2 U P FLOW SWITCH SET 70 58 88 46 45 OUT1 OUT2 DOWN 2-Port size 45 4-5.5 36 (42.2) 60 46 Flow direction 21 Digital
W : W max. value is from
70 200 100 60 60 Air consumption Air consumption 150 50 50 75 40 40 100 50 30 30 20 20 50 25 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 1.0 2.0 3.0 4.0 5.0 6.0 Supply pressure [MPa] Supply pressure [MPa] Flow rate Characteristics Flow rate characteristics Supply pressure: 0.4MPa Supply pressure: 0.4MPa 100 90 100 90 Vacuum pressure [kPa] Vacuum pressure [kPa] 80 80 70 70 60 60 50 50 40 40 30 30
70-&' r q.oo 3, 24.4 l z.9 -3r 5l 25 ,{ 25 N/A 14.3 L45 300 e.60 -g' r 2.rof're.oo t? 25.4 12.9'3r ) t 25 25 PM2050g[(S] 306 l9.0fdo ?
speed Air cushion Cushion None (non-lube) Lubrication JIS class 2 Thread tolerance to 1000st +1.4 Stroke length tolerance Basic type, Axial foot type, Front (Rear) flange type Mounting brackets Stroke Table Energy Absorption/Cushion Stroke Unit: mm Bore size (mm) Maximum Note 2) stroke Standard Note 1) stroke Bore size (mm) Max. energy absorption [J (kgfcm)] Effective cushion stroke (mm) 7 (70