Supply 15 to 30 VDC to the power supply for communication. Check the power supply for communication voltage.

Description Qty 1 Rod cover 1 2 Head cover 1 3 Cylinder tube 1 4 Piston rod 1 5 Piston 1 6 Cushion ring 1 7 Cushion ring B 1 8 Bushing 1 9 Cushion valve 2 10 Snap ring 2 11 Tie rod 4 12 Tie rod nut 8 13 Wear ring 1 14 Rod seal 1 15 Piston seal 1 16 Cushion seal 2 17 Cushion valve seal 2 18 Cylinder tube gasket 2 19 Piston gasket 1 20 Rod end nut 1 21 Magnet (1) 33 Revision history A: 125

When auto switches D-M9/M9W/Y59 D-M9A D-Y7, Y7W are used A B L Auto Switch Hysteresis MHZ When auto switches D-M9V/M9WV/Y69 D-M9AV D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. MHF A B MHL L MHR MHK MHS Max.

: inch (mm) 10mm N 3/8 B Q E D A G C F 1 J 31.5 [820] P L K M N H (L=2800) IDFB4E/6E/8E/11E-11 1. : inch (mm) 10mm N 3/8 A B E D Q G C F 1 J 31.5[800] H N M 4-0.5 (L=2800) [4-13] 6-3 6 3 IDFB Series IDX-OM-W020 6 IDFB15E-11 1. : inch (mm) 10mm N 3/8 E D B A Q G C F (820) K L P N M H J 4-13 (L=2800) (inch [mm]) A B C D E F G H J K L M N P Q IDFB3E 3/8 8.9 16.1 18.6

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.

15 0 0 0 2 4 6 8 10 12 14 16 18 20 0 5 10 15 20 25 30 35 40 45 50 55 60 Flow rate (L/min) Flow rate (L/min) If the circulating fluid flow drops below 0.53 gpm (2 L/min)., the shutdown alarm activates and operation stops.

material Grade B Fluororubber Weight 360 g 730 g 360 g 730 g Dimensions Dimensions other than below are the same as the standard type.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -34No.PS-OMW0002-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

B 23.5 A 7.0 B A 10.5 (13.0) B Bore size 50 63 80 23.5 19.5 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values inside ( ) are for the D-A96/A96V.

No.PS-OMT0002-E PRODUCT NAME Digital Gap Checker MODEL / Series / Product Number ISA3-##A/B-# 2 switch outputs (NPN or PNP) OUT1: Distance detection OUT2: Pressure or distance detection Table of Contents Before Use Safety Instructions 2 Features 7 Model Indication and How to Order 8 Summary of Product parts 14 Specification 15 About this product Specifications (ISA3) 15 Specifications

on the part of the manufacturer. 2008 SMC Corporation All Rights Reserved VG300-OMH0002-B

Locking slotted type 3 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 4 7 1 5 6 24 VDC 12 VDC 7 240 VAC 50/60 Hz 15 (11) 2 Nil: Non-locking push type 9 Other 20 (14) 3 Option 25 (16) 4 Valve size 2 to 9 1 1 1 4 32 (22) 5 1 B 1 4 Flange 32F 40A 1 1 2 40 (28) 6 1 B 1 2 Flange 40F Electrical entry/With light/surge voltage suppressor 50A Nil Air operated 2 50 (33) 7 GS Grommet with surge

Spacer Y20 Seal for additional station ISA-7-B End plate L ISA-6-A End plate R ISA-6-B ISA-7-A When a 2 port solenoid valve is connected to the right: When 2 air catch sensors are connected or when a 2 port solenoid valve is connected to the left: Joint bracket ISA-3-A Lead wire with connector (Individual wiring type) ISA-8-A ISA-8-B Bracket ISA-4-A DIN rail mounting bracket ISA-9-A Straight

MK/MK2 RSQ/RSG RSH A CE1 Auto switch mounting position Auto switch model D-Z7l D-Z80 D-Y59 D-Y7P D-Y69l D-Y7PV D-Y7lW D-Y7BAL D-Y7lWV CE2 ML2B Bore size (mm) A B A B A B A B 20 18 8 18 9.5 18 2 18 4 ML1C 32 13.5 10 13.5 12 13.5 4.5 13.5 6.5 50 21.5 12 21.5 14 21.5 6.5 21.5 8.5 REA 63 16.5 31 16.5 33 16.5 25.5 16.5 27.5 80 26 33 26 35 26 27 26 29 REC RHC How to Install an Auto Switch MTS To

VE 3 4 1 3 4, 1 1 1 1 4 1 2 , 2 VY1 G Dimensions: Auto Feed Tank PPA AL Float switch Contact point capacity: AC: 15 VA, DC: 15 W Contact point construction: 1a, 1b Width across flats 12 Float switch Lubrication plug Model A 174 174 234 234 B 70 70 108 108 C 16 16 30 30 D 7 7 7 7 E 91 91 121 121 F 182 182 242 242 G 15 15 16 16 H 24 24 40 40 I 382 382 422 422 J 414 414 472 472 K 428 428 L

G H AV OUT port AU AF 4-12 mounting hole Silencer (Option) O EXH port: 1 position AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F EXH port: 1 position D E IR A 300 404 B 126.5 167 C 53 96 D 73 116 E 118 150 F 98 130 G 46 62.8 H 43 62 I 60.5 90 J 18 17 K 15 15

flats 12 Float switch Lubrication plug Model A 174 174 234 234 B 70 70 108 108 C 16 16 30 30 D 7 7 7 7 E 91 91 121 121 F 182 182 242 242 G 15 15 16 16 H 24 24 40 40 I 382 382 422 422 J 414 414 472 472 K 428 428 L ALT-5 ALT-5-IS ALT-9 ALT-9-IS 449 482 14-13-9 Oil Distributor VA, VB/Nylon Tubing Related Products: Oil Distributor Series VA, VB How to Order V A 4 6 Applicable tubing O.D.