Magnet: None, Mounting: G (MF2, Rear Flange), Bore Size: 400 (4"), Stroke: 0500 (5"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
Magnet: D (Built-in), Mounting: X (MP1, Double Rear Clevis), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)
Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
TU0425 TU0604 TU0805 TU1065 TU1208 TIUB01 TIUB05 TIUB07 TIUB11 TIUB13 Color 100 m reel Black, White, Red, 200 m reel X3 Blue, Yellow, Green, 400 m reel Clear, Orange 500 m reel X4 20 m roll Red, White, Yellow, Green, Clear, Orange 373 Soft Polyurethane Tubing Series TUS Suitable for piping in confined spaces Extremely flexible Soft polyurethane tubing Model/Specifications 20 m roll
M&I 400 software. 0.00000 lb. H25.
Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor: 400 W, Maximum speed: 1000 mm/s, Dust/Drip proof specification *, RoHS compliant ELECTRIC ACTUATOR. ROD TYPE ELECTRIC ACTUATOR. 5.84000 lb. A38.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor: 400 W, Maximum speed: 1000 mm/s, Dust/Drip proof specification *, RoHS compliant ELECTRIC ACTUATOR. ROD TYPE ELECTRIC ACTUATOR. 17.61600 lb. A38.
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: M (Applicable to Deionized Water Piping)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K