This trimmer is used to adjust the offset voltage (ion balance). IZF21/31 series ionizers are marked with “ADJUST” on the front of the product.
For details on adjusting the offset voltage, refer to the operation manual.
The IZF series operation manual can be found here.

When abnormal discharge occurs for longer than 100 ms, the incorrect high voltage alarm will be activated. Discharge may be caused by foreign matter or water droplets adhering to the emitter (electrode needle). In order to clear the alarm, remedy the cause of the error after stopping the power supply, and then turn the power ON again.