Bore Size: 20mm, Port Type: NPT, Stroke: 20mm, Stroke Adjustment: 0 to 10, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Adjustable Stroke, Extension Type, Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control
or 1342 22, 38, 70 or 1342 IO-Link master Class B EX600-LBB1 1 (4 ports) 22, 38, 70 or 1342 22, 38, 70 or 1342 1: Not available for EX600-SEC1/2 compatibility mode. 2: The allocated bytes of the IO-Link master can be changed by the IO-Link master size setting switch. -80No.EX-OMA1023 Details of I/O map of the IO-Link master unit I/O map of the IO-Link master unit is described below.
Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Differential temp. of 3 oC Differential temp. of 6 oC Heat Radiated between inside and between inside and Model kW outside of installation outside of installation area area HRS018-A-20--R Approx. 4 70 40 HRS030-A -20--R Approx. 6 100 60 3.2 Installation HRS-R Series 3-6 HRX-OM-W058 Chapter 3 Transport
Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Differential temp. of 3 oC Heat Differential temp. of 6 oC Radiated between inside and Model between inside and outside kW outside of installation of installation area area HRS050-A-20 Approx.10 140 70 The water-refrigerated thermo-cooler discharges heat by using facility water.
circuit Detects abnormal current/voltage or heat or fanlock. 3 Low recirculating fluid level Level sensor Detects lowering of recirculating fluid level in reservoir. 4 Detection of breakage of temp. sensor Controller internal circuit Detects breakage and short circuit of temp. sensor and cables. 5 Excessive temp. increase Controller internal circuit Detects temp. input value not less than 70
HART Communication 30 h Pistonrod Retract end Moving area Output current value Total time (h) Display time (h) Piston movement 0% 5% ~5% ~4.8mA 3.125 3 10% 5~10% 4.8~5.6mA 0.625 0 10~30% 5.6~8.8mA 2.5 2 30% 30~50% 8.8~12mA 6.25 6 50% 50~70% 12~15.2mA 2.5 2 70% 70~90% 15.2~18.4mA 7.5 7 90% 95% 90~95% 18.4~19.2mA 1.875 1 100% 95%~ 19.2mA~ 5.625 5 Extended end (Set point by calibration) Total
(Becomes close to the trapezoidal acceleration as the setting value reaches 0) Acceleration and deceleration ratio 10 10 10 10 to 100 EQFS251 to 50 EQFS321 to 70 EQFS401 to 70 Torque when held *2 50 70 70 Sets the torque when stopped after the positioning operation. (Unit: %) H 140 80 80 Sets the position loop P constant.
90.00 0.50 No.00[mm] 100[mm] 1AREA 100[mm]-0.5[mm]=99.5[mm] INPON [mm] c 100 0 [mm/s] b INP ON OFF INP [mm] k 100.5 99.5 0 10 20 30 40 50 60 70 80 90 100 [mm] 2AREA AREA1 2 180[mm] 290[mm] AREAON 100[mm]-0.5[mm] = 99.5[mm] [mm] c 2[mm] j 1[mm] j 100 0 [mm/s] b ON AREA OFF INP ON OFF INP [mm] k 100.5 99.5 0 10 20 30 40 50 60 70 80 90 100 [mm] 2 -25- -IN INPAREA a b c d e f
Prior to the shipment of a SMC product to another country, assure that all local rules goveming that export are known and followed. ollowed. ollowed. ollowed. 3 VP4*50*-OMC0001-B VP4* * * *50/VP4* * * *70/VVP4* * * *0 Series Precautions for 5 Port Air Operated Valve 1 1 1 1 Be sure to read before handling. 10.
Location where the ambient temperature is out of the following range: In transportation and In storage 0 to 50C (with no water or circulating fluid in piping) In operation *Power supply 100V : 5 to 35C *Power supply 200/230V : 5 to 40C Location where the ambient humidity is out of the following range or where condensation occurs: In transportation and storage 15 to 85% In operation 30 to 70%
60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20 30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 12-10-4 4 Series MHY2/MHW2 180 Angular Style Air Gripper MHZ MHW2-32D MHW2-50D MHW2-20D MHF 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa MHL 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 MHR 200 0.5 0.5 0.5
70 4 104 Rc 1/8 Rc 1/8 62 7 7 40 125 60 32 M8 x 1.25 13 38 M12 x 1.75 depth 21 115 11 82.5 4 115 67 8 8 45 150 75 38 M8 x 1.25 14 47 WH W X Y T U V W Z Bore size (mm) 20 25 32 40 30 23 30 112 146 182 16 53 50 30 25 37 132 167 199 20 63 60 25 28.5 37 132 167 202 60 20 63 20 33 44 162 210 227 25 73 70 Without Rear Plate Stroke range (mm) Long Stroke Bore size (mm) 20 25 32 40 Bore size (mm
After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.
60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20 30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 12-10-4 4 Series MHY2/MHW2 180 Angular Style Air Gripper MHZ MHW2-32D MHW2-50D MHW2-20D MHF 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa MHL 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 MHR 200 0.5 0.5 0.5