SMC Corporation of America
Elite Part Number Search
Search Results "11-CDM2XB40-250"

Note 3) Station numbers are started from D side although connector is mounted on D or U Side. 11 VFR3000-OMH0003-B TROUBLE SHOOTING (14) Excessive supply oil amount (11) Intrusion of foreign matter Wrong Pressure supplied X port.

Note 5) M and MO type connectors cannot be selected for the model with the pressure sensor or the pressure switch for vacuum. 11 - Doc. no.

Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

Solenoid valve (11) SYJ319Plate assembly (12) XL1AV16-90-2 63 80 Valve size Description Part indication No. Solenoid valve (11) SYJ519Plate assembly (12) XLAV63-90-1 Note 1) The at the end of the solenoid valve part number is the selection symbol for voltage, electrical entry, and other specifications. For details about selection symbols, refer to the Web Catalog.

On : Output Off : Not output On, Off Off 11 Upper/Lower Temp. Alarm Sequence * How to return default value: Turn on the power supply with pressing [SEL] and [RET] keys.

Replace pilot valve assembly. (10) Protect the valve so that water does not splash the coil. (11) To remove foreign matter,air blow piping, then replace valve.

Mounting of standard auto switch 11 Standard Auto Switch Mounting The standard auto switch cannot be used in a magnetic field environment. For information on our cylinders that can be fitted with a magnetic field resistant auto switch, please refer to page 9.

No.EX-OMP0013-E PRODUCT NAME SI unit for EtherNet/IPTM MODEL / Series / Product Number EX260-SEN# Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Definition and terminology 10 Installation and Wiring 11 Installation 11 Wiring 12 LED Indication and Settings 16 Hardware configuration 19 EDS file and icon 19 Setting using RSLogix5000TM

29.5 31 25 11.5 14 16.5 26 28.5 7.5 10 12.5 30 32.5 32 12 13 15.5 25 27.5 8 9 11.5 29 31.5 40 15 20 20 32 32 11 16 16 36 36 50 14.5 21 21 33 33 10.5 17 17 37 37 The value of W in the table means the amount of auto switch protrusion from the body end surface.

Fittings & Tubing Air Cylinders Rotary Actuators How to Order 11 Vacuum suction type Clean series 11 M D H R 3 10 R M9B S 22 M D H R 3 10 R M9B S Copper, fluorine and silicone-free + Low particle generation Number of auto switches 2 pcs. 1 pc.

Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.

M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9 90.2 91.9 90.2 91.9 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5

Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-

Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.

(Ex.: 2504-N002) Construction/Parts/Dimensions AN103 AN203 Construction/Parts/Dimensions VEX AN AMC AN303/403 AN200 to 900SAN, #1 to #8 AN202 to 402SAN, #9 to #11 AN103 to 403SAN, #12 to #15 5.2-2

) 3-M3 X 0.5 thread depth 6 44 MDHR2-15E port position 42 B 45 120o 11 120o A C 36 M3 X 0.5 M3 X 0.5 Finger opening port Finger closing port 10 M3 X 0.5 Finger opening port M3 X 0.5 Finger closing port 25o 25o MHZ2 MHZJ2 6-M3 X 0.5 thread depth 6 (A, B, C common view) MHQ 3-3 depth 6 +0.02 0 34 (A, B, C common view) MHL2 12h9 0 -0.043 Auto switch mounting groove MHR 1.5 .

Wiring 1) Pass them through the cable (7) in the order of cable ground (4), washer (5), rubber seal (6), and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note) Tighten within the tightening torque of 0.5 Nm 15%.

MSUA3 MSUA3-S/SE 8 x M4 x 0.7 depth 7 C 58 36 44 B 27 30 4 x M4 x 0.7 depth 5.5 22.5 5 +0.025 0 41h9 0 0.062 3H9 A +0.052 0 21H9 Long groove depth 5 (Positioning pin hole) 22.5 29 2.5 3 3 x 3H9 depth 3 +0.025 0 2 x 4.5 through ( A , B , C ) 15.5 45 9 42h9 0 0.062 2 36 3 8 11 8 1.5 5 5 18.3 29 11 Angle adjustment bolt 2 x 4.5 through 6 2 x M5 x 0.8 Adjustment: Max. 8.2 6 B port A port 0.5

To booster lube From booster lube To booster lube From booster lube A B 63 63 80 85 90 100 C Port size Rc INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model 1 4 3 8 15 15 15 20 22 22 141 164.5 170 180 230 251 , , 1 4 3 8 1 2 B C D E F Port size Rc Part no. A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19

Rod cover Tolerance h9 Clean room series Series 10-, 11-CUJ Two auto switches can be installed even for 4mm strokes.