SMC Corporation of America
Elite Part Number Search
Search Results "ZK2P00K5NL2A-08-B"

System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Connector: L-type Plug Connector, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached)], Pump System PE Port Female Thread: -, Individual

System: Vacuum Pump System, Single Unit, Valves: Supply Valve; Self-holding, Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: B [One Bracket for Mounting Single Unit, (Mounting

System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor, -100 to 100, Analog Output 1 to 5 V, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached

System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; None, Rated Voltage: 12 VDC, Vacuum Sensor: Pressure Sensor, -100 to 100, Analog Output 1 to 5 V, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached

System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only, Connector: L-type Plug Connector, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached)], Pump System PE Port Female

System: Vacuum Pump System, Single Unit, Valves: Supply Valve; Self-holding, Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: B [One Bracket for Mounting Single

Main Body Shape: Unit, Additional Function: Silencers / Valves for Vacuum Generation / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 90, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Individual

Main Body Shape: Unit, Additional Function: Silencers / Filter / Valves for Vacuum Generation / Reverse Check Valve/Vacuum Retention / LED Display Pressure Switch for Vacuum / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 58, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø8, Air Supply Port Connecting Shape

Main Body Shape: Unit, Additional Function: Silencers / Filter / Valves for Vacuum Generation / Reverse Check Valve/Vacuum Retention / LED Display Pressure Switch for Vacuum / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 58, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø8, Air Supply Port Connecting Shape

Main Body Shape: Unit, Additional Function: Silencers / Filter / Valves for Vacuum Generation / Reverse Check Valve/Vacuum Retention / LED Display Pressure Switch for Vacuum / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 90, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø8, Air Supply Port Connecting Shape

Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Reverse Check Valve/Vacuum Retention / LED Display Pressure Switch for Vacuum / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 90, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø8, Air Supply Port Connecting Shape: One-Touch

Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Reverse Check Valve/Vacuum Retention / LED Display Pressure Switch for Vacuum / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 90, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø8, Air Supply Port Connecting Shape: One-Touch

Fuse Cutout FLT 08 ALARM09 Reservoir High Temp. FLT 09 ALARM10 Return High TempWRN 10 ALARM11 Reservoir High Temp.

Symbol Differential pressure indication Symbol Nominal filtration 0 None 4 Differential pressure indicator standard 074 74m 5 Differential pressure indication switch 105 105m 003 3m Table1-1 Port size (Rc) 005 5m Non-standard 010 10m Port size Threaded connection 020 20m Symbol 040 40m 149 149m 06 3/4 270 270m 08 1 10 1 1/4 12 1 1/2 16 2 20 2 1/2 24 3 10 / 17 FGX-OM-F001-A 2.

Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.

Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 Flow

Body size Metric size 06 08 10 12 Inch size 07 09 11 13 3 4 5 6 1/8 1/4 3/8 1/2 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 1/8 1/4 3/8 1/2 01 02 03 04 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.

Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.

Vertical Suction Filter FHIA Series How to Order FH I A N 04 M M R 074 Vertical suction filter Relief valve Hydraulic fluid R D N W V With relief valve None (Blanking plate) Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication Differential pressure indicator Differential pressure indication switch Note) Port size M E D 04 06 08 10 12 16 20 24 28 32 1/2B None

/Cap (Resin part only) RBC C 08 Applicable model 08 10 14 20 27 RBC2015 RBC2725 RBC0805, 0806 RBC1006, 1007 RBC1411, 1412 Cap Cap cannot be mounted for basic type. Please place an order with cap type from the beginning.