SMC Corporation of America
Elite Part Number Search
Search Results "VV5F3-40-102-02"

Stainless Steel Body for Low Breakway Friction Double Roc/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: Standard, Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: Standard, Semi-Standard 2: W (Drain Cock w/Barb Fitting for ø6 x ø4 Nylon Tube)

Body Size: 40, Thread: N (NPT), Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: 1 (0.02 to 0.2MPa Setting)

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Standard

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)

method A Air-cooled refrigeration Specications Model HRL100-Am-20 HRL200-Am-20 HRL300-Am-20 CH1 CH2 CH1 CH2 CH1 CH2 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 1.4 2.2 3.0 Control method PID control Ambient temperature [C] 2 to 45 Circulating uid CH1: Tap water/CH2: Tap water, Deionized water1 Set temperature range [C] CH1: 15 to 25/CH2: 20 to 40

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: 1R (1 + R)

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: R (Flow Direction: Right to Left)

Body Size: 40, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 02 (1/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Standard

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: Standard

Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard

Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes

Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF3000 series manifold, Metric threads [Rc(PT)], Manifold type: S mount, Maximum stations: 10, Port sizes: 1/8, 1/4, Common

Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF3000 series manifold, Metric threads [Rc(PT)], Manifold type: S mount, Maximum stations: 10, Port sizes: 1/8, 1/4, Common