Allowable M1 (= M3) moment (Nm) Load weight (kg) Cylinder stroke (mm) 32 Allowable Moment (M2) (Nm) 10 16 20 25 Bore size (mm) CXWM 0.108 0.549 0.809 1.029 2.695 Cylinder speed (mm/s) CXWL 0.108 0.549 0.809 1.201 2.695 Note) M2 is steady regardless of the strokes. 8-26-6 5 Series CX Before Operation 1. Changing from the non-auto switch specifications to the auto switch specifications 2.
Pulling force (N) Stroke (mm) Bore size (mm) Rubber cap Thread size 2 20, 25, 32 M2.5 x 0.45 x 25 or more 4.9 40, 50, 63 M3 x 0.5 x 30 or more 10 3 80, 100 M5 x 0.8 x 40 or more 24.5 3 Remove the bolt for normal operation. It can cause lock malfunction or faulty release. 2. Manual release, Lock type While pushing the M/O knob, turn it 90 counterclockwise.
(Applicable bolt size is M3.) These grooves can be used for firmly fixing the tying bands of lead wires of the auto switch, etc., and also terminal boards, etc., to the main body of the cylinder. When the terminal block is fixed on a cylinder directly.
Bore size (mm) 40, 50, 63 Screw size M3 x 0.5 x 30l or more Pulling force (N) 10 Stroke (mm) 3 Remove the bolt for normal operation, otherwise it can cause lock malfunction or faulty release. 8-25-28 28 Series MGZ/MGZR Made to Order Specifications: Please consult with SMC for detailed specifications, delivery and prices. 1 Rod End One Female Threaded Hole Rod End One Female Threaded Hole
Bore Size: 10mm, Port Thread: (M3 Thread-6)(M5 Thread-10~15mm)(Rc-20~63mm), Stroke: 400mm
Bore Size: 40mm, Port Thread: (M3 Thread-6)(M5 Thread-10~15mm)(Rc-20~63mm), Stroke: 350mm
Actuation: Normally Open, Body: Body Ported, Port Size: M3 x 0.5, Bracket: w/Bracket
Actuation: Normally Closed, Body: Body Ported, Port Size: M3 x 0.5, Bracket: w/Bracket
Actuation: Normally Open, Body: Body Ported, Port Size: M3 x 0.5, Bracket: -
Actuation: Normally Closed, Body: Body Ported, Port Size: M3 x 0.5, Bracket: -
Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: CM1 (CC-Link Ver. 1. 10), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable
Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable:
Model Screw size Max. tightening torque [Nm] LEPY6 M3 x 0.5 0.9 LEPS6 LEPY10 M4 x 0.7 1.4 LEPS10 It may damage and malfunction. If the operation is interrupted or stopped during the cycle: When the pushing operation command is output immediately after restarting the operation, the direction of movement depends on the position of restart. Side mounting (Body tapped) 2.
O-ring NBR 8 Spring Stainless steel 9 Pin Stainless steel 3 Pinch Valve LPV Series Dimensions Light position (Option) 24 Lead wire length Grommet type (Option) 73 Lead wire length 73 5 Panel thickness: 3 mm or less 83.1 2 x 2.7 Mounting hole thread size: M2.5 Proper tightening torque: 0.25 to 0.35 Nm 19.5 L1 7.45 L2 26.8 20.3 D 19.5 Recommended panel hole dimensions for valve mounting 2 x M3
MACM6 X114 118 125 125 97 113 33.8 53 28 33.3 30 43 X115 59 6 98 60 X116 57 4 60 MACM10 X114 185 197 198 11 152 182 18 53.8 77 31 24 13 0 53.3 50 70 X115 83 6 108 X116 81 4 5 Centering Unit MACM Series Dimensions P: Port side photo sensor mounted type B: Port back side photo sensor mounted type Mounted example of EE-SX671 made by OMRON P: Port side photo sensor mounted type 4 19 2 x M3
Specifications Specifications ISO Class 3 With M5 fitting (Applicable tubing O.D. 6) Cleanliness Bleed hole L For low temp. environments 30 to 60C Special NBR T For high temp. environments 5 to 100C Fluororubber Symbol Environment Ambient temperature Rubber material IR1000/2000 series: With M5 fitting (Applicable tubing O.D. 6) IR3000 series: Rc1/2 female thread EXH port IR1000 series: With M3
Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3000-A and the current IR3000 Comparison between IR1000-A/IR2000-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units
Relation between Operating Temperature and Maximum Operating Pressure Particulate Generation Classifications 105 1.2 Particle concentration (Particles/m3) Maximum operating pressure MPa ISO class 6 1.0 104 ISO class 5 0.8 103 ISO class 4 0.6 102 ISO class 3 0.4 10 0.2 0.1 0.5 1 1 0 -5 0 20 40 60 Operating temperature C Particle diameter (m) Note) Refer to SMC Pneumatic Clean Series (CAT.E02
Model Screw size Max. tightening torque [Nm] A [mm] L [mm] EQFS16 M3 0.6 3.5 23.5 EQFS25 M4 1.5 4.5 24 EQFS32 M5 3.0 5.5 30 EQFS40 M6 5.2 6.6 31 Body mounting Maintenance Warning Body mounting reference plane For housing B bottom Maintenance frequency Positioning pin (Reference plane) Perform maintenance according to the table below.
When the nozzle is clogged : If the nozzle is clogged, loosen the set screw (M3 x 0.5 hexagon socket head screw), remove the nozzle from the body and clean it. 4.Use a nylon tube to connect the liquid collector with the strainer.