V3 L 1 H 2 4 10 40 Connections Temperature range NPT 1/4 inch 40 to 140F (40 to 60C) (No freezing) 25% to 75% of the scale: 2%F.S.
SI SI -Enable / 68 No.EX-OMU0020CN . 12-2 SF LED () No. 6.2 3 LED Link Power Margin 2dB . 12-3 US LED No. 1 US1 LED SI US1(/) SI 2 US1 LED US1(/) 3 US2 LED SI US2(/) SI 4 US2 LED US2(/) 69 No.EX-OMU0020CN . 12-4 No. SI 1 US2(/) SI 12.2. EX245-DX1 . 12-5 EX245-DX1 No. / 1 / US1(/ SI / / 2 EX245-DX1 LED / / / 12.3.
A One-touch fitting for 12 is attached to each port.
Port size(R) 12 Max. Operating Pressure (MPa) 0.7 Max. Operating temp.
CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly
L dimension 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 VZ 285.5 21 273 No.
-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 2 2 2 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA mA mA Command signal Command signal Command signal VY1700 1 VY1900 1 Input signal voltage (current) for starting the operation of a pilot valve VY1D0 (direct operated)
circuit Reed auto switch Solid state auto switch 12 V 5 V, 12 V IC circuit Diagnostic indication (2-color) Relay, PLC Yes Yes Grommet 24 V 12 V 5 V, 12 V IC circuit Water resistant (2-color indication) M9PAV M9PA M9BAV M9BA 12 V P3DW Magnetic field resistant (2-color indication) 2-wire (Non-polar) 3-wire (Equiv.
I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 AL01 : Low level in tank abnormal 1 AL02 : Low level in tank 2 AL03 : Phase loss / phase reverse error 7 3 AL04 : Water leakage 1 4 AL05 : Pump inverter error 2 5 AL06 : Internal fan stop 3 Alarm flag 1 6 AL07 : Fan Inverter error 8 7 Unused 8 AL09
O 1 (O P71) V (V P71) 6/12 FGX-OM-L009-B FGESL Series IN/OUT -0.1MPa (P10) (M12) IN OUT O O V 40 () () () 7/12 FGX-OM-L009-B 1 G1/8 () (R1 R2) IN (Rp1/4) (R3/4) DRAIN OUT (Rp1/4) (R1 R2) (R3/4) 1 1 SUS304 O FGE-OP007 8 NBR FKM O (NBR) (FKM) M10X1.5 1 SUS304 M10 SUS304 SUS304 SUS316WPA FGE-OP005 SUS316 SUS304 SUS304 FGD-OP001 SUS316 FGE-KT001 NBR O FGE-KT002
Display resolution-switch function kPaMPa switch function Converts the unit between kPa and MPa. 3 Series ZSE30A(F)/ISE30A Internal Circuits and Wiring Examples Z/ISE30A(F) Output N P NPN (1 output) PNP (1 output) Brown DC (+) Brown DC (+) Load Main circuit Main circuit Main circuit Main circuit + + 12 to 24 VDC 12 to 24 VDC Black OUT Black OUT Load FUNC FUNC Blue DC () Blue DC () Max.
50 60 Body size Body size X430 X440 Low temperature 20 25 30 40 50 60 High temperature Thread type Thread type Rc NPT G Nil N F Rc NPT G Nil N F Port size Port size Body size Port size Body size Symbol Port size 25 30 40 50 60 Symbol 20 25 30 40 50 60 02 03 04 06 10 1/4 01 02 03 04 06 10 1/8 3/8 1/4 1/2 3/8 3/4 1/2 1 3/4 Option Note 1) 1 Symbol Nil B G Note 2) Applicable model AR25 to 60
Table. 11-1 Length the EX245 series module n 0 1 2 3 4 5 6 7 8 L 113.6 167.6 221.6 275.6 329.6 383.6 437.6 491.6 545.6 Formulas: L = 54n + 113.6 (max. 8 modules) (Dimensions in mm) -57No.EX##-OMU0020-A 12. Troubleshooting 12.1. EX245-SPN1/SPN2 Table. 12-1 Troubleshooting for bus communication No. Problem Possible cause Remedy 1 LINK indicator is OFF.
Cylinder Position of rotational axis: Parallel side b and through the center of gravity Position of rotational axis: Through the center of diameter and gravity 2 3 2 2 a r a I = m 12 I = m 12 3. Thin rectangular plate (Including 8.
15.2 51.3 28.2 41.9 46.9 46.5 41.5 19.8 23 14 R 3/8 19 40 35 10 ASD530F-03-10S 98 21 54.1 32.6 18.5 23.1 12 ASD530F-03-12S 101 22 55.9 34.4 20.9 10 ASD630F-04-10S 177 21 64.3 32.6 18.5 57.3 64.8 57.6 50.1 18.6 R 1/2 49.6 42.1 26.5 28.6 25.9 24 12 ASD630F-04-12S 179 22 66.1 34.4 20.9 Reference dimensions of M5 x 0.8, R threads after installation. 15-9-16 4 Dual Speed Controller with One-touch
18.5 93 28.2 51.3 15.2 41.9 46.9 46.5 41.5 23 19.8 14 R(PT)3/8 19 40 35 10 ASD530F-03-10S 21 98 32.6 54.1 18.5 23.1 12 22 ASD530F-03-12S 101 34.4 55.9 20.9 10 21 177 ASD630F-04-10S 32.6 64.3 18.5 57.3 64.8 57.6 50.1 18.6 R(PT)1/2 49.6 42.1 28.6 26.5 25.9 24 12 22 179 ASD630F-04-12S 34.4 66.1 20.9 Reference dimensions of M5 X 0.8, R(PT) thread after being screwed in. 4.1-15 Dual Speed Controller
VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1k Black OUT 12 to 24VDC + 12 to 24VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE (-) side.
Apply a tightening torque of 8 to 12 Nm.
Adjustable Mounting Height Type Series RSG 40, 50, Stopper Cylinder How to Order 30 D RSG 40 Standard Type C73 40 30 D RSDG With Auto Switch Number of auto switches With auto switch Nil S 2pcs. 1pc. (internal magnet) Nil Without auto switch Auto switch type Bore size 40 50 40 mm 50 mm Select applicable auto switches from the table below.