If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 6 Filter Rc1/2 20m 7 Pressure gauge 0 to 1.0MPa Y-strainer Rc1 #40 HRS-S0212 Install either the strainer or filter.
-9 5m LE-CYM-S5A-9 LE-CYM-R5A-9 750W 10m LE-CYM-SAA-9 LE-CYM-RAA-9 20m LE-CYM-SCA-9 LE-CYM-RCA-9 3m LE-CYB-S3A-5 LE-CYB-R3A-5 5m LE-CYB-S5A-5 LE-CYB-R5A-5 100W 10m LE-CYB-SAA-5 LE-CYB-RAA-5 DRIVER End 20m LE-CYB-SCA-5 LE-CYB-RCA-5 3m LE-CYB-S3A-7 LE-CYB-R3A-7 Motor 5m LE-CYB-S5A-7 LE-CYB-R5A-7 with lock 200W 400W cable for with lock (2) 10m LE-CYB-SAA-7 LE-CYB-RAA-7 20m LE-CYB-SCA-7 LE-CYB-RCA
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 6 Filter Rc1/2 20m Note FQ1011N-04-T020-B-X61 Note) The filter shown above cannot be directly connected to the thermo-chiller.
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 6 Filter Rc1/2 20m Note FQ1011N-04-T020-B-X61 Note) The filter shown above cannot be directly connected to the thermo-chiller.
Filter Rc1/2 20m HRS-PF003 or HRS-PF004 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.
Filter Rc1/2 20m HRS-PF003 or HRS-PF004 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.
However, the maximum value that can be set for this movement amount per rotation (AL) parameter is 20.0m(20m). Set the movement amount per rotation (AL) so that it does not exceed this maximum value. Movement amount per rotation (AL) = PB1/n = Movement amount per rotation (AL) Unit magnification (AM) 7.3 Stroke limit Wiring for stroke limit.
Specifications General Specifications -5 to 50oC (Without pressure sensor and pressure switch, With pressure switch, Ambient temperature range With pressure switch with energy saving function) (No condensation) 0 to 50oC (With pressure sensor) Fluid Air 30m/s2 (Without pressure sensor and pressure switch, With pressure sensor) Vibration resistance Note 1) 20m/s2 (With pressure switch) 150m
Specifications General Specifications -5 to 50oC (Without pressure sensor and pressure switch, With pressure switch) 0 to 50oC (With pressure sensor) Ambient temperature range 5 to 50oC (With pressure switch with energy saving function) (No condensation) Fluid Air 30m/s2 (Without pressure sensor and pressure switch, With pressure sensor) Vibration resistance Note 1) 20m/s2 (With pressure
Type of Seal Metal Rubber Fluid Air, Inert Gas Air, Inert Gas Min Operating Pressure Max Operating Pressure (Note1) 0.75MPa / 109 PSI 0.75MPa / 109 PSI Effective Area (Cv Factor) mm 2 1 Metal Rubber Single 2.5 (0-14) 2.7(0-15) Double 2.5 (0-14) 2.7 (0-15) 3-Position 2.0 (0-11) 2.7 (0-15) Single Max 12m sec Max 15m sec Response Time (Note 2) Double Max 10m sec Max 13m sec 3-position Max 20m
Filter Rc1/2 20m HRS-PF003 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.
CRBU2 T Single round shaft Double shaft (Long shaft without key and with our chamfers) J CRB1 K Double round shaft MSU CRJ CRA1 Dimensions (mm) J (Double shaft/Long shaft without key & with four chamfers) CRQ2 T (Single round shaft) K (Double round shaft) Shaft type MSQ MRQ DConfiguration 20M 20 22 25 30 UU 118 139 167 202 D (g6) 15 17 20 25 D (g6) 15 17 20 25 H 36 41 50 60 H 36 41 50 60
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CRA1 Dimensions (mm) J (Double shaft/Long shaft without key & with four chamfers) CRQ2 T (Single round shaft) K (Double round shaft) Shaft type MSQ MRQ DConfiguration 20M 20 22 25 30 UU 118 139 167 202 D (g6) 15 17 20 25 D (g6) 15 17 20 25 H 36 41 50
The element service indicator is shipped mounted to the micro mist separator with prefilter, and cannot be retrofitted or used with the single style. 14-19-48 45 Made to Order Specifications Series IDG Dimensions/With Element Service Indicator IDG3M/5M/10M/20M IDG3HM/5HM/10HM/20HM (A) (B) K (D) C L H 37 J IN OUT M F (E) (G) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco
Tajima Musen Denki Company Max Transmission Distance 20m (6 core twisted pair shielded wire) Position Detection Method Magnetive Scaled Piston Rod & Detection Head (50cm cable.
(Example) Load weight 300kg, Transfer speed 20m/min, Friction coefficient = 0.1 RE A B (How to read graph) In graph (2), find the intersection of the vertical axis representing the weight of 300kg and the horizontal axis representing the speed of 20m/min. And select the bore size 63 positioned within the operating range of the cylinder.
Note 1 Valve Rc1/2 2 Filter Rc1/2 20m HRS-PF003 If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more HRS-R Series 3.4 Piping 3-21 HRX-OM-W058 Chapter 3 Transport and Setting Up 3.5 Fill of circulating fluid Turn the tank lid anticlockwise to open.
Filter Rc1/2 HRS-PF003 or 20m HRS-PF004 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more HRS-R Series 3.4 Piping 3-21 HRX-OM-X027 Chapter 3 Transport and Setting Up 3.5 Fill of circulating fluid Turn the tank lid anticlockwise to open. Supply the circulating fluid up to the H mark on the fluid level indicator.
Green Yelow Brown Grey Brown Pink Brown Blue Blue Red Red Black L 20 1-13 2M2.6x0.45 53.5 15.2 25 L 41 41 53 D-sub connector cable ass'y Electric characteristics Item Characteristics Conductor resistance /km, 20C Cable length (L) Ass'y No. 57 or less GVVZS3000-21A-1 GVVZS3000-21A-2 GVVZS3000-21A-3 GVVZS3000-21A-4 GVVZS3000-21A-5S Connector made in conformity with DIN47100. 1m 3m 5m 8m 20m
TU0212 B 20 Length per roll Tubing model Symbol 20 Roll size 20m roll Caution Color Symbol B W R BU Y G C Color Black White Red Blue Yellow Green Clear 1 Applicable for general industry water. Please consult with SMC if using for other kinds of fluids. Surge pressure must be under the max. operating pressure.