ANR: 20C atmospheric pressure, relative humidity 65% 200 300 1,000 1 4 3 8 1 4 3 4 1 2 , , 0.12 AMC-EL2 BE20 0.2 AMC-EL3 BE30 0.5 AMC-EL5 BE50 VEX How to Order AN 5 1 0 AMC 06 AMC Thread Body size Suffix Port size 1 4 std. 3 8 std. 3 4 1 std. std. 1 2 2 std. 2 std. 3 5 6 8 9 B With bracket 1 2 14 20 1 1 02 Female Female Male Female Female Male 1 Male thread 10 1 4 Male Male Male D Drain piping
Rc 1/8 7 ~ 9 Rc 1/4 12 ~ 14 Fluid Compressed Dry Air 7 Limitations of Use Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Exhaust Cleaner Series AMC How to Order Ensures clean plant air and reduces noise pollution; Over 35 dB (A) noise reduction Over 99.9% oil mist removal 5 1 0 AMC 06 Thread Body size Suffix std. 1 4 std. 3 8 std. 3 4 1 std. 1 std. 1 2 2 std. 2 3 5 6 8 9 B With bracket 1 Male thread D Drain piping (Except AMC220) (1) (2) 2 Female thread Note 1) Female thread: Available only AMC220, 320, 520
01 Work piece Vacuum regulator Body size 1 2 3 IRV1000 type IRV2000 type IRV3000 type Leak tester Pressure transducer Solenoid valve Solenoid valve Work piece Vacuum pump IRV Filter Thread type Nil N F Rc NPT G Optional Inspection equipment Port size Solenoid valve Application IRV Work piece Tank Vacuum pump Filter Symbol Bore IRV1000 IRV2000 IRV3000 01 02 03 04 1/8 1/4 3/8 1/2 Flow meter
(Nil) ID Case material Material Resin Aluminum Stainless steel Symbol 0 1 2 Port size Connection size Note IDG Symbol C04 C06 C08 C10 C12 02 N02 F02 4 6 8 10 12 IDK SFD100 only Clean One-touch fittings (KP series) Symbol 1 and 2 are made to order. For details, refer to page 325.
Example)AC30-F03DM-KSTV-13NR-A q r t y w e q Symbol Bodysize Description 20 25 30 40 Rc NPT G Nil N F Threadtype w + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 Portsize e + Floattype autodrain a Withoutautodrain N.C.(Normalclose)Drainportisclosedwhenpressureisnotapplied. N.O.(Normalopen)Drainportisopenwhenpressureisnotapplied.
EX9-PE1 power input connector No.1 M12 5-pin plug B-code Element No. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.
Mounting bracket Minimum order quantity Bore size [mm] Contents 20 25 32 40 Mounting nut (M5, Rc1/8, NPT1/8) 1 1 JSN-020B JSN-032B JSN-040B 1 mounting nut Rod end nut 1 NT-02 NT-03 NT-04 1 rod end nut Refer to page 10 for dimensions. 1 Can be used for M and MZ only.
1 Digital Pressure Sensor Series GS40 Specifications F.R.L. Multiple features Pressure sensor and switch in one compact body; Economical use of space; Simplified operation; Combined functions. Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
[Pressure center] B C 4-position dual 3-port (N.C. + N.O.) Note) For symbol, refer to page 7. U side Base mounted plug-in 3 1 2 Stations D side 9
1 Digital Pressure Sensor Series GS40 Specifications F.R.L. Multiple features Pressure sensor and switch in one compact body; Economical use of space; Simplified operation; Combined functions. Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
KS KX KM KF M H/DL L/LL KC KK KK130 Color Weight Model Applicable tubing size Applicable tubing material DM Nylon, Soft nylon Polyurethane TG-1 Metric size 4, 6 1/8", 1/4" Blue 33 g TG-2 Inch size Red KDM KB How to Use KR Caution Process 1. Tool edge should be pushed straightforward into the edge of the release button along with the tube in the axial fitting direction.
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
Description Regenerative absorption unit power output (negative) Regenerative absorption unit power output (positive) Max. 6mA External power supply 24VDC N 1 Resistor R P B + 5 Input Temperature sensor (NC) Control equipment (PLC, etc. ) Connector: Molex 5258-02 Pin: Molex 5167PBTL Crimping tool: JHTR2445A LC1 connection cable (0.5m) LC1 connector (preassembled) (2P) 6 Regenerative absorption
Aleignt should be ued. @ 690 kPa llOO p6i): 45ON tlOolbl with x-ht-2:1 optbn: gooN (2mtb) -5o: somm 11.97"1 Sr6ke 150: 150mm {5.905"1 Weiqhl -50: 4.6k9 ilo 2b) Weight 150: 5.2k9 111.3bl Max Presure: 1,7OOkP8 (25O psD 1 6 N E M d t h v e s E A D p | . d F i a .150N ( l00lbs xRAY-450-50 XRAY-450-50-POB i50N (l(l0lbst xRAY-450150 450N ( lOOlbs xRAY-450150-POB XRAY-450-50 Weld Spatter Covers
(English 1 pc./Japanese 1 pc.), Operation Manual (for installation/operation) 2 pcs. (English 1 pc./Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs.
Ported P,A,B Ports 1), Thread: N (NPT)
Function: 1 (2 Position Single), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 1 (Direct Manual Override for Base Mounted Type), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1),
Function: 1 (2 Position Single), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 1 (Direct Manual Override for Base Mounted Type), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1),
Delivery Pressure: 02 [1 to 30 psig (0.007 to 0.2 MPa)], Material: B (Body: Brass; Poppet: 316 SS; Diaphragm: 316 SS), Ports: 5PC [5 Ports (1-In; 2-Out; 3-Extra Bottom Port Out; 4-Gauge Port In, 5-Gauge Port Out)], Connections, Inlet: 4 (NPT 1/4 Inch), Connections, Outlet: 4 (NPT 1/4 Inch), Gauge Port, Extra Bottom Outlet: 0 (No Pressure Gauge, Connections: 1/4 Inch NPT), Gauge Port, Inlet