SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-04-M3"

Replacement procedure of shock absorber Loosen the hexagon socket head set screw (M3) at the piston rod by approximately one turn, and push down the lever. (See Fig. 11) Tool Hexagon wrench: Width across flats 1.5mm While pushing down the lever, remove the shock absorber and replace it with a new shock absorber. Tighten the hexagon socket head set screw (M3 x 0.5) of the piston rod.

(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.

Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.

M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision C: Limited warranty and Disclaimer and measurement laws are added.

As the indicator LED protrudes from the switch unit, mounting the switch bracket above the LED may cause damage to it. (4) Insert the auto switch mounting screw (M3) included in accessories from the mounting hole of the auto switch mounting band, inserting the through hole of the switch bracket.

Screw Max. tightening torque (Nm) Maximum screw-in depth (mm) MHZ2-6 MHZJ2-6 M3 x 0.5 0.88 10 MHZA2-6 MHZAJ2-6 Model No. Screw Max. tightening torque (Nm) MHZ2-6 MHZJ2-6 M2.5x0.45 0.49 MHZA2-6 MHZAJ2-6 8 - Caution 1. Avoid twisting the gripper when mounting an attachment. Any damage to the gripper may cause malfunction and reduce the accuracy. 2. Avoid external force to fingers.

CUX16-PS Proper tightening torque (Nm) (cylinder body) 10 16 20, 25 32 Hexagon socket head cap screw size (mm) M3 Bore size (mm) Rod seal 1 pc. CUX20-PS Gasket 1 pc. CUX25-PS 0.5410% Grease pack (10g) 1 pc. CUX32-PS M4 1.2310% Seals cannot be replaced for 10mm bore size. M5 2.5510% M6 4.0210% 2.

MVGQ 10 16 20, 25 32 0.54 10% M3 CUX32-PS Grease pack (10 g): 1 pc. 1.23 10% M4 It is impossible to replace seals in bore size 10 mm. CC 2.55 10% M5 4.02 10% M6 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1.

A Mounting screws (M3 x 8L) (accessory) Waterproof seal (accessory) Panel mount adapter Power supply/Output connection cable ZS-26-A Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (accessory) Waterproof seal (accessory) Panel mount adapter Panel Options When only optional parts are required, order with the part numbers listed below.

Be aware that the output circuit is not active immediately after the power is connected. 3.1-12 PSE100 Dimensions A: Panel mount 56 l50 Gasket (Accessory) 7.4 l48 PRESSURE SWITCH 10 8 l 45 A Panel mount adaptor (Accessory) 55 11.4 Cover for display (Optional) 62 4 X 7.5 (= 30) 6.5 7.5 10-M3 2-M3 X 8L 30 View A Cutout dimensions for panel mount 65 or more 45 +0.6 0 +0.6 0 45 +0.6 0 N pieces

Mist generation pressure differential (MPa) IC EX: How to obtain the mist generating pressure differential if the flow rate obtaine in 1. above is 35 m3/min and the line pressure (inlet pressure P1) is 0.7 MPa: Extend horizontally from the point at which the flow rate is 35 m3/min to obtain the point that intersects with P1 = 0.7 MPa.

A Mounting screws (M3 x 8L) (Accessory) Waterproof seal (Accessory) Panel mount adapter Power supply/Output connection cable ZS-26-A Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (Accessory) Waterproof seal (Accessory) Panel mount adapter Panel Option When only optional parts are required, order with the part numbers listed below.

Signal Cable Specications Power cable Terminal specications Cable specications Terminal block screw diameter Recommended crimped terminal 0.75 mm2 (AWG18) Shielded cable M3 Y-shape crimped terminal 1.25Y-3 Signal cable 15 Partially enlarged view A Series HRS100/150 Thermo-chiller Standard Type List of Function Operation Display Panel The basic operation of this unit is controlled through

(Tightening torque of M3 screw should be 0.5 to 0.7 Nm.) 5. Modification of the detecting position should be made in the condition of 3. Auto switch Auto switch mounting nut Auto Switch Mounting Bracket Part No.

Description Phillips Screw Tightening Torque 1 2 Gauge nut O-ring For IRV10(A): M3 For IRV20(A): M4 0.32 0.03 Nm 0.76 0.05 Nm Rc1/8 8 Vacuum Regulator Series IRV10/20 Pressure Gauge for Vacuum GZ43-K-01 IRV20 GZ33-K-01 IRV10 Part no.

Size: 1 (M3, M5 Basis), Style: 4 (Flat Elbow), Control Method: 0 (Meter-out), Thread: Rc (Metric M3, M5; Unified 10-32UNF), Port Size: M3 (M3X0.5), Option: None, Lock Nut: J (Round)

Size: 1 (M3, M5 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Thread: Rc (Metric M3, M5; Unified 10-32UNF), Port Size: M3 (M3X0.5)

Size: 1 (M3, M5 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Thread: Rc (Metric M3, M5; Unified 10-32UNF), Port Size: M3 (M3X0.5), Option: None, Lock Nut: J (Round)

Size: 1 (M3, M5 Basis), Style: 4 (Flat Elbow), Control Method: 0 (Meter-out), Thread: Rc (Metric M3, M5; Unified 10-32UNF), Port Size: M3 (M3X0.5)

Danger: Switch ON At normal output Switch OFF Maintenance Time [s] M3 x 5 L M3 x 5 L Operator How to reset the product after a power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing.